Output
Terminals
4
1 and 2
5
3 and 4
6
5 and 6
7
7 and 8
NOTE
A:
When control option condition occurs, contacts close. Contacts are normally open when power is off.
B:
When control option condition occurs, contacts open. Contacts are normally open when power is off.
C:
Control option 6 provides an output signal when a potential fault is detected. If control option 3 and 6 are both used,
then both a fault output and an alert output signal will be present when the fault LED turns on.
E 2014 Nordson Corporation
To set up a digital output
Set up the parameter control option for each output that you connected to the
melter. Table 3‐9 lists the available control options. Refer to Setting Up the
Melter earlier in this section for information about how to select operating
parameters and edit parameter control options.
Table 3‐9 Digital Output Data
Operating
Parameter
43
0 ‐ Output Disabled
1 ‐ Ready (Default)
2 ‐ Ready and the Motor is On
44
3 ‐ Fault
4 ‐ Not used
45
5 ‐ Service LED is On
6 ‐ Alert
9 = Heaters On
46
10 = Standby Output
14 = Motor Running
Control Options
3-39
Installation
Note
A
A
B
A
C