DX80...C Wiring
Wiring power to the DX80...C models varies depending the power requirements of the model. Connecting dc power to the communication
pins (Tx/Rx) causes permanent damage. For FlexPower devices, do not apply more than 5.5V to the B+ terminal.
Terminal Label Gateway, DX85
V+
10 to 30V dc
Tx/+
RS485 / D1 / B / +
V-
dc common (GND)
Rx/-
RS485 / D0 / A / -
B+
Terminal Block (IP67 Housing)
For the IP67 housing models, PWR in the wiring diagram refers to SP1 or SP2 on the wiring board.
GND GND
SP2
SP1
CMB
CMA
DO2
DO1
DO4
DO3
GND
GND
DI1
DI1
DI4
DI3
Terminal Block (IP20 Housing)
For the DX8x...C models, PWR in the wiring diagram refers to V+ on the wiring board and GND in the wiring diagram refers to V- on the
wiring board. Ignore alternate labeling referring to other models that use this board.
FlexPower Discrete Models
B+. 3.6 to 5.5V dc (for battery powered
models only).
DIx. Discrete IN x.
DOx. Discrete OUT x.
RX/-. Serial comms line for Gateways and
DX85s only. No connection for Nodes.
4
Wire No.
Wire Color
10 to 30V dc Powered Nodes
1
Brown
10 to 30V dc
2
White
3
Blue
dc common (GND)
4
Black
5
Gray
10 to 30V dc Powered Nodes
10 to 30V dc
dc common (GND)
CMx. Serial interface connection. For non-serial interface models, do not make
any wiring connections to these terminals.
DIx. Discrete IN x.
DOx. Discrete OUT x.
GND. Ground/dc common connection.
SPx. Switch Power. Provides variable power sources for external devices.
Ignore alternate labeling referring to other models that use this board.
FlexPower Serial Interface Models
B+. 3.6 to 5.5V dc (for battery powered models
only).
CMx. Serial interface connection. For non-seri-
al interface models, do not make any wiring
connections to these terminals.
DIx. Discrete IN x.
DOx. Discrete OUT x.
www.bannerengineering.com - tel: 763-544-3164
SureCross DX80 FlexPower Node
Battery Powered Nodes
dc common (GND)
3.6 to 5.5V dc
Battery Powered Nodes
dc common (GND)
3.6 to 5.5V dc
FlexPower Counter Models
B+. 3.6 to 5.5V dc (for battery powered
models only).
CIx. Counter IN x.
DIx. Discrete IN x.
DOx. Discrete OUT x.
RX/-. Serial comms line for Gateways and
DX85s only. No connection for Nodes.
P/N 136328 Rev. F