Banner SureCross DX80 FlexPower Manual

Counter node
Hide thumbs Also See for SureCross DX80 FlexPower:

Advertisement

Quick Links

SureCross DX80 FlexPower Counter Node
Configurable Node with an integrated battery, 1 selectable counter input, 1 selectable discrete input, and 1 discrete NMOS output
For additional information, updated documentation, and accessories, refer to Banner Engineering's website,
ing.com/surecross.
Models
Frequency
DX80N9X1S2A1
900 MHz ISM Band
DX80N2X1S2A1
2.4 GHz ISM Band
Internal antenna models are also available. For more information, contact your local Banner Engineering Corp. representative.
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to serious
injury or death. This device does not include the self-checking redundant circuitry necessary to allow its
use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-
energized sensor output condition.
SureCross User Configuration Tool
Setting Up Your Wireless Network
To set up and install your wireless network, follow these steps:
1. Configure the DIP switches of all devices.
2. Connect the sensors to the SureCross devices.
3. Apply power to all devices.
P/N 136972 Rev. F
The SureCross® wireless system is a radio frequency network with integrated I/O that can operate in
most environments and eliminate the need for wiring runs. Wireless networks are formed around a
Gateway, which acts as the wireless network master device, and one or more Nodes.
• Wireless industrial I/O device with one selectable discrete input, one selectable counter input
(rate or event; sinking, sourcing, or self-energized), and one NMOS discrete output
• User selectable 10 kHz event counter or 25 kHz rate counter
• FlexPower® technology driven by one lithium primary battery integrated into the housing
• DIP switches for user configuration
• Frequency Hopping Spread Spectrum (FHSS) technology and Time Division Multiple Access
(TDMA) control architecture ensure reliable data delivery within the unlicensed Industrial, Scien-
tific, and Medical (ISM) band
• Transceivers provide bidirectional communication between the Gateway and Node, including
fully acknowledged data transmission
• Lost RF links are detected and relevant outputs set to user-defined conditions
Environmental Rat-
ing
IP67, NEMA 6
The User Configuration Tool (UCT) offers an easy way to link I/O points in your wire-
less network, view I/O register values graphically, and set system communication pa-
rameters when a host system is not part of the wireless network.
The UCT requires a special USB to RS-485 (model number BWA-UCT-900 for 1 Watt
radios, BWA-HW-006 can be used for all other radios) converter cable to pass infor-
mation between your computer and the Gateway. Download the most recent revi-
sions of the UCT software from Banner Engineering's website:
gineering.com/wireless.
5/22/2013
I/O
Inputs: One selectable discrete, one selectable counter
Outputs: One NMOS sinking discrete
www.bannerengineer-
http://www.banneren-
0 136972
0

Advertisement

loading

Summary of Contents for Banner SureCross DX80 FlexPower

  • Page 1 DX80N2X1S2A1 2.4 GHz ISM Band Internal antenna models are also available. For more information, contact your local Banner Engineering Corp. representative. WARNING: Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death.
  • Page 2: Configuring The Dip Switches

    For additional information, including installation and setup, weatherproofing, device menu maps, troubleshooting, and a list of accesso- ries, refer to one of the following product manuals. • SureCross Quick Start Guide: Banner part number 128185 • SureCross Wireless I/O Network Manual: 132607 •...
  • Page 3 SureCross DX80 FlexPower Counter Node Switches Device Settings Report Rate 1 second * Default configuration Address Mode The SureCross wireless devices may use one of two types of addressing modes: rotary dial addressing or extended addressing. In rotary dial address mode, the left rotary dial establishes the network ID and the right rotary dial sets the device ID. The wireless network is restricted to a maximum of 16 devices.
  • Page 4 SureCross DX80 FlexPower Counter Node Debounce. Debounce establishes how to examine a signal’s transitions. The factory de- Device switches fault setting is to activate the input filtering to compensate for unclean state transitions. To turn off the input filtering, set the switch to the ON position.
  • Page 5: Modbus Register Table

    SureCross DX80 FlexPower Counter Node Modbus Register Table Modbus Holding Register I/O Type Holding Register Repre- I/O Range Point sentation Gateway Nodes Min. Max. Min. (Dec.) Max. (Dec.) 1 + (Node# × 16) Discrete IN 1 5 + (Node# × 16)
  • Page 6 SureCross DX80 FlexPower Counter Node Node Reg 15 0x8F Node Reg 16 D3D9 Node Reg 7 0x8F The counter has been preset to 20,567,001 (0x0139 D3D9) Preset Using the Node’s Menu System To manually enter a counter preset, follow the LCD menu flow using the diagram shown.
  • Page 7: Specifications

    SureCross DX80 FlexPower Counter Node To replace the lithium "D" cell battery in any integrated housing model, follow these steps. 1. Remove the four screws mounting the face plate to the housing and remove the face plate. 2. Remove the discharged battery and replace with a new battery. Only use a 3.6V lithium battery from Xeno, model number XL-205F.
  • Page 8 When using other antennas, verify you are not exceeding the transmit power levels allowed by local governing agencies. Consult with Banner Engineering Corp. if the destination country is not on this list.
  • Page 9: Banner Engineering Corp Limited Warranty

    ER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp.