RESIDENCE
7

PROGRAMMING THE BOILER

- Position the system's master switch to the "on" position.
If necessary, the interface automatically goes to the clock menu. On the
main screen the icons
,
00:00 is displayed with the first two digits blinking with a frequency of 0.5
sec ON, 0.5 sec OFF.
To set the time and day follow the following instructions:
ƒ set the hour with the
and
ƒ set the minutes with the
ƒ set the day of the week with the
the day selected blinks, press MENU at the icon
time and day setting. The clock blinks for 4sec and then returns to the
main screen
ƒ to exit the time programming without saving the modified values, just
press
.
NOTE: It is possible to change the TIME and DAY settings also later by
accessing the SETTING menu at the TIME parameter, or by pressing the
A+C keys for at least 2sec.
A
+
Each time that the boiler is powered a vent cycle is carried out lasting 4 min.
The display shows the message <<VENT AIR PURGING CYCLE IN
PROGRESS>> lighting up the icon RESET
To interrupt the vent cycle press RESET.
Set the boiler to OFF by pressing
34
,
and
and ENTER come on while
arrows, then confirm with A
arrows, then confirm with A
and
and
arrows. The segment of
Enter
per to confirm the
C
+
RESET
MENU
.
8

FIRST COMMISSIONING

- Position the system's master switch to the "on" position.
- Open the gas tap to allow fuel to flow
ƒ With power on the backlight comes on, then all the icons and the
segments come on for 1sec and in sequence the firmware revision is
displayed for 3sec:
ƒ Then the interface displays the status active at that moment.
Vent cycle
b
Each time that the boiler is powered, an automatic vent cycle is
carried out lasting 4 min. When the air purging cycle is in progress, all
heat requests are inhibited except those for domestic hot water when
the boiler is not set to OFF and a scrolling message is displayed on
the interface screen "AIR PURGING CYCLE IN PROGRESS".
The purge cycle can be interrupted early by keeping key 2 pressed for at
least 2 seconds (the icon RESET comes on).
The purge cycle can also be interrupted, if the boiler is not set to OFF, by a
domestic hot water request.
ƒ Adjust the ambient temperature thermostat to the desired temperature
(~20°C) or, if the system is equipped with a programmable thermostat
or timer, ensure that the thermostat or timer is "active" and set correctly
(~20°C)
ƒ Then set the boiler on WINTER or SUMMER depending on the type of
operation desired.
ƒ The boiler will start up and continue working until the set temperatures
are reached, after which it will then go back to standby.
8.1
Operating status
For changing the operating status from WINTER to SUMMER to OFF press
key 1 until the icon for the desired function is displayed.
WINTER MODE
ƒ Set the boiler to the WINTER status by pressing key 1 until both the
domestic hot water icon and the heating icon are displayed.