OTD CURVES
This parameter allows you to set the number of the compensation curve
used by the boiler when in thermoregulation.
The factory setting for this parameter is 2.0 for high temperature systems
and 0.5 for low temperature ones.
The parameter can be set with the range 1.0 - 3.0 for high temperature
systems, 0.2 - 0.8 for low temperature ones.
See paragraph "4.5 Setting the thermoregulation" for more details about this
function.
NIGHT COMP
With this parameter you activate the "night compensation" function.
The default value is 0, set to 1 to activate the function.
See paragraph "4.5 Setting the thermoregulation" for more details about this
function.
POR
This parameter allows you to enable the heating timing programming.
Programming timing not enabled = 0
When the room thermostat contact closes the heat request is always met
without any time limitation.
Programming timing enabled = 1
When the room thermostat contact closes the heat request is enabled
according to the programming timing that has been set.
MAN AUTO
This parameter allows you to set the way of mode for passing from manual
heating to automatic heating.
The factory setting for this parameter is 0: in this condition the passage
from manual to automatic timing programming should be done by the user
pressing the keys C+D.
Set the parameter to 1 to activate the function: in this condition the passage
from manual to automatic timing programming occurs automatically at the
first change of the band.
ZONE1 ENABLE
This parameter allows you to activate the management of an additional
heating zone (the use of the BE16 accessory board is required, not supplied
as standard).
The default value is 0, set to 1 to activate the function.
Note: this parameter cannot be changed when an OT+ chronothermostat is
connected.
ZONE1 ADDR
When ZONE1 ENABLE = 1, this parameter allows you to set the address of
the BE16 board of zone 1.
The factory setting is 1 and can be set within the 1 - 6 range.
Note: see the instruction sheet of the BE16 accessory board for more
information about the use of this parameter.
ZONE1 HYDRAULIC CONFIG
When MAIN ZONE ACTUATION TYPE = 1, this parameter allows you to set
the hydraulic configuration of heating zone 1.
The factory setting for this parameter is 0 and allows you to manage a direct
zone, set to 1 to manage a mixed zone.
Note: see the instruction sheet of the BE16 accessory board for more
information about the use of this parameter.
ZONE1 TYPE
When MAIN ZONE ACTUATION TYPE = 1 this parameter allows you to
specify the type of zone to be heated, .
It is possible to choose from the following options:
0 = HIGH TEMPERATURE (factory setting)
1 = LOW TEMPERATURE
ZONE1 SET
When MAIN ZONE ACTUATION TYPE = 1, this parameter allows you to the
setpoint value of heating zone 1. The factory setting for this parameter is
ZONE1 MAX CH SET and can be programmed within the ZONE1 MIN CH
SET and ZONE1 MAX CH SET range.
ZONE1 MAX CH SET
This parameter allows you to specify the maximum heating setpoint that can
be set for zone 1:
- range 20°C - 80.5°C, default 80.5°C for high temperature systems
- range 20°C - 45°C, default 45°C for low temperature systems.
Note: the ZONE 1 MAX CH SET value cannot be less than ZONE1 MIN CH
SET.
ZONE1 MIN CH SET
This parameter allows you to specify the minimum heating setpoint that can
be set for zone 1:
- range 20°C - 80.5°C, default 40°C for high temperature systems
- range 20°C - 45°C, default 20°C for low temperature systems
Note: the ZONE1 MIN CH SET value cannot be greater than ZONE1 MAX
CH SET.
ZONE1 OTR
This parameter allows you to activate thermoregulation mode for zone 1
when the system has an outdoor temperature sensor connected.
The factory setting is 0, the boiler always operates for zone 1 at a fixed point;
to have the boiler work in climate mode connect an outdoor temperature
sensor and set the parameter to 1, connect an outdoor temperature sensor.
With an outdoor temperature probe disconnected the boiler always operates
at a fixed point.
See paragraph "4.5 Setting the thermoregulation" for more details about this
function.
ZONE1 OTD CURVES
This parameter allows you to set the number of the compensation curve for
zone 1 used by the boiler when in climatic mode.
The factory setting for this parameter is 2.0 for high temperature systems
and 0.5 for low temperature ones. The parameter can be set with the range
1.0 - 3.0 for high temperature systems, 0.2 - 0.8 for low temperature ones.
See paragraph "4.5 Setting the thermoregulation" for more details about this
function.
ZONE1 NIGHT COMP
This parameter allows you to activate "night compensation" for zone 1.
The default value is 0, set to 1 to activate the function.
See paragraph "4.5 Setting the thermoregulation" for more details about this
function.
DHW
MIN DHW SET
NOT AVAILABLE ON THIS MODEL
MAX DHW SET
NOT AVAILABLE ON THIS MODEL
DHW DELAY
This parameter allows you to set the delayed starting of the boiler in domestic
hot water mode.
The factory setting for this parameter is 0 and can be programmed within
the range 0 - 60sec.
SUN ON
This parameter allows you to activate the following functions related to the
operation of the boiler in domestic hot water mode:
0 = no function; the boiler is domestic hot water mode starts immediately
and uses the related domestic hot water thermostats, i.e. it switches off
at setpoint +5°C and switches back on at setpoint +4°C (factory setting)
1 = domestic hot water delay function, so the boiler in domestic hot water
mode starts with a delay equal to the value of the parameter DHW
DELAY
2 = FUNCTION NOT AVAILABLE ON THIS MODEL
3 = la the boiler uses absolute domestic hot water thermostats, i.e. in
domestic hot water mode it always switches off at 65°C and switches
back on at 63°C, independently of the domestic hot water setpoint that
has been set
4 = functions 1 and 3 are active
SOLAR
FSUN
This parameter is used to enable the management of the solar storage
cylinder, the BE15 accessory board must be used.
the factory setting is 0 = solar storage cylinder management disabled, set
the parameter to 1 to enable the function.
T MAX TANK
The parameter allows you to set the maximum temperature of the top part of
the storage cylinder. The factory setting is 60°C.
The parameter can be set with the range 10°C - 130°C.