Riello RESIDENCE KIS Series Installer And User Manual page 17

Hide thumbs Also See for RESIDENCE KIS Series:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 4
- TIME ON, is displayed again, then the programming of the time bands
is resumed up to the maximum number of programmable bands (four),
Enter
or else
is pressed to confirm the bands set and you move on to the
programming of the next day.
For each day of the week it is possible to programme up to 4 bands, each
one having a start time and an end time.
Outside these time bands, heat requests from the room thermostat are
ignored.
The central heating time bands enabled by default are:
07:30 - 08:30 / 12:00 - 13:30 / 18:00 - 22:30 from MON to FRI
08:00 - 22:30 from SAT to SUN.
When heating programming timing is enabled pressing the keys C+D allows
you to move from AUTO programming timing to MAN ON or MAN OFF.
+
4.4
Boiler configuration
To access the boiler configuration menu, access the technical parameters
menu, as indicated in the paragraph "3.21 Access to the parameters" .
Use the
and
arrows to scroll through the parameters of the pre-
selected sub-menu, confirming the selection with A; change the value of the
pre-selected parameter with C and D confirming the selection with the key
indicated by the icon
.
Enter
Description of the settings menu
Some of the following functions might not be available depending on the
access level and the type of machine.
SETTING
TIME
From this menu the time and the number of the day of the week can be
adjusted.
TIME PROGRAM
From this menu you can access the menu for adjusting the heating
programming timing. For each day of the week it is possible to set up to 4
bands, characterised by a starting time and an end time.
It is possible to access the same menu directly from the main screen by
pressing the keys B+D at the same time for at least two seconds (see
paragraph "4.3 Time band scheduling function (room thermostat)").
+
C
D
RESET
MENU
COMB
GAS TYPE
This parameter allows you to set the type of gas.
0 = methane gas - factory setting
1 = LPG
BOILER TYPE
Set this parameter for the type of boiler, see the relative paragraph "4.27
Replacing the AKM board" for more information.
COMBUSTION OFFSET
This parameter allows you to reset the factory settings of the combustion,
see the relative paragraph "4.28 Combustion Control Parameters" for
more information.
CONF
HYDRAULIC CONFIGURATION
This parameter allows you to set the type of hydraulic configuration of the
boiler:
0 = ONLY HEATING
1 = INSTANTANEOUS FLOWSWITCH
2 = INSTANTANEOUS FLOWMETER
3 = STORAGE CYLINDER WITH PROBE
4 = STORAGE CYLINDER WITH THERMOSTAT
The factory setting for this parameter is 1. When replacing the electronic
board make sure that this parameter is set to 1.
WATER TRANSDUCER
This parameter allows you to set the type of water pressure transducer:
0 = water pressure switch
1 = pressure transducer
The factory setting for this parameter is 1, do not change! When replacing
the electronic board make sure that this parameter is set to 1.
AUTO WATER FILL ENABLE
This parameter allows you to enable the "semi-automatic filling" function
since the boilers have a pressure transducer and a filling solenoid valve
installed.
The factory setting for this parameter is 0, do not change! When replacing
the electronic board make sure that this parameter is set to 0.
BEGIN SYSTEM FILLING
NOT AVAILABLE ON THIS MODEL
AIR PURGING CYCLE
This parameter allows you to disable the vent cycle function; the factory
setting is 1, set the parameter to 0 to disable the function.
MIN
This parameter allows you to change the minimum number of the fan's rpm.
Do not change!
MAX
This parameter allows you to change the maximum number of the fan's rpm.
Do not change!
MAX_CH
This parameter allows you to change the maximum number of the fan's rpm
in heating mode. Do not change!
RANGE RATED
This parameter allows you to change the heat output in heating mode, the
factory setting for this parameter is MAX_CH and can be programmed within
the MIN - MAX_CH range.
For more information about the use of this parameter see the paragraph
"4.19 Range rated".
ENGLISH
17