6
CONTROL PANEL (see "3.21 CONTROL
PANEL")
A
+
B
1
7

PROGRAMMING THE BOILER

- Position the system's master switch to the "on" position.
If necessary, the interface automatically goes to the clock menu. On the main screen the icons
,
,
and
and ENTER come on while 00:00 is displayed with the first two digits
blinking with a frequency of 0.5 sec ON, 0.5 sec OFF.
To set the time and day follow the following instructions:
ƒ set the hour with the
and
ƒ set the minutes with the
and
ƒ set the day of the week with the
Enter
blinks, press MENU at the icon
blinks for 4sec and then returns to the main screen
ƒ to exit the time programming without saving the modified values, just press
NOTE: It is possible to change the TIME and DAY settings also later by accessing the P1.02
parameter in the P1 menu, or by pressing the A+C keys for at least 2sec.
A
+
ƒ If you need to set the language, select the menu P1 and confirm your choice using .
ƒ Use the arrows to display parameter P1.01, then enter the submenu by pressing .
buttons to set the desired language – see "3.22 Menu structure" . To
ƒ Use the
and
Enter
confirm your choice, press
+
RESET
MENU
2
3
arrows, then confirm with A
arrows, then confirm with A
and
arrows. The segment of the day selected
per to confirm the time and day setting. The clock
+
RESET
MENU
.
C
Each time that the boiler is powered a vent cycle is carried out lasting 4 min.
The display shows the message -AIR lighting up the icon RESET
D
To interrupt the vent cycle press RESET.
Set the boiler to OFF by pressing
8

FIRST COMMISSIONING

- Position the system's master switch to the "on" position.
- Open the gas tap to allow fuel to flow
ƒ With power on the backlight comes on, then all the icons and the segments come on for 1sec
and in sequence the firmware revision is displayed for 3sec:
.
C
ƒ Then the interface displays the status active at that moment.
Vent cycle
b
Each time that the boiler is powered, an automatic vent cycle is carried out lasting 4 min.
When the air purging cycle is in progress, all heat requests are inhibited except those
for domestic hot water when the boiler is not set to OFF and the -AIR is displayed on
the interface screen.
.
ENGLISH
25