Cisco 1552S Installation Manual page 61

Hazardous locations
Table of Contents

Advertisement

Chapter 3
Installing the 1552 Series Access Points in Hazardous Locations
Table 3-1
Materials Required
Ground lug and screws (provided with access point)
Crimping tool for ground lug, Panduit CT-720 with
CD-720-1 die (http://onlinecatalog.panduit.com)
Four M8 or 5/16 in. (31 mm) screws
Four wall anchors (specified for wall material)
Drill bit for wall anchors
Electric drill and standard screwdriver
#6-AWG ground wire
Shielded outdoor-rated Ethernet (CAT5e or better) cable
Grounding block
Grounding rod
13-mm box-end wrench or socket set
Caution
The mounting surface, attaching screws, and optional wall anchors must be able to support a 50-lb
(22.7 kg) static weight.
Material Needed to Mount Access Point to a Vertical Wall
Cisco Aironet 1552 Series for Hazardous Locations Installation Guide
Mounting on a Wall or a Pole