GLP KNV Series Quick Start And Safety Manual page 32

Table of Contents

Advertisement

www.glp.de
KNV Dot arrays containing single Dots between columns
Warning!
Any KNV Dot that is not part of an independently supported column must
be fastened on both sides to KNV Dots that are in independently supported
columns: do not create an installation where any KNV Dot is supported on
only one side.
See Figure 17. You can create
an array of KNV Dots with
single Dots installed between
full columns of Dots, but you
must observe the following
precautions:
• Use the instructions given in
the section 'Array where at
least every second column
is supported' starting on
page 30 as a guide.
• Make sure that the columns
on the left- and right-hand
edges of the array and
every second column inside
the array are complete,
unbroken columns of Dots
and that they are correctly
supported using rigging
clamps.
• Respect the maximum limit
of five Dots vertically.
• Make sure that any single
Dot that is installed
between full columns is
fastened to Dots on both
sides using GLP Slide
Connectors.
32
Every second
Every column
at edge
independently
of array
supported and
supported and
with no gaps
with no gaps
Figure 17. KNV Dot array with single
Dots between full columns
KNV Dot and Line Quick Start and Safety Manual Rev. A
Every column
column
at edge
of array
supported and
with no gaps

Advertisement

Table of Contents
loading

This manual is also suitable for:

Knv dotKnv lineKnv psu

Table of Contents