Planning The Electrical Installation; What This Chapter Contains; Motor Selection And Compatibility - ABB ACQ800 Series Hardware Manual

Table of Contents

Advertisement

ACQ800-37 Hardware Manual

Planning the electrical installation

What this chapter contains

This chapter contains the instructions that you must follow when selecting the motor,
the cables, the protections, the cable routing and the way of operation for the drive
system.
Note: The installation must always be designed and made according to applicable
local laws and regulations. ABB does not assume any liability whatsoever for any
installation which breaches the local laws and/or other regulations. Furthermore, if
the recommendations given by ABB are not followed, the drive may experience
problems that the warranty does not cover.

Motor selection and compatibility

1. Select the motor according to the rating tables in chapter
DriveSize PC tool if the default load cycles are not applicable.
2. Check that the motor ratings lie within the allowed ranges of the drive control
program:
•motor nominal voltage is 1/2 to 2 · U
•motor nominal current is 1/6 to 2 · I
3. Check that the motor voltage rating meets the application requirements:
If the drive is equipped with ...
diode supply
(ACQ800-U1)
IGBT supply
(ACQ800-31, ACQ800-37)
U
U
U
U
U
voltage. For units with IGBT supply: see the parameter value. Note: Nominal DC link voltage is U
U
See notes 6 and 7 below the
0 to 2 · I
in scalar control. The control mode is selected by a drive
2hd
parameter.
= Rated input voltage of drive
N
= U
/ 1.35
ACeq1
DC
= U
/ 1.41
ACeq2
DC
= Equivalent AC power source voltage of drive in V AC
ACeq
= Maximum DC link voltage of drive in V DC. For resistor braking, U
DC
× 1.41 in V DC.
N
of the drive
N
of the drive in DTC control and
2hd
... and ...
no resistor braking is used
frequent or long-term brake cycles
are used
DC link voltage is not increased from
nominal (through parameter settings)
DC link voltage is increased from
nominal (through parameter settings)
Requirements table.
Technical
data. Use
... then the motor voltage
rating should be ...
U
N
U
ACeq1
U
N
U
ACeq2
= 1.21 × nominal DC link
DC
N
Planning the electrical installation
53
× 1.35 or

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acq800-37

Table of Contents