Power module replacement (Frame R8i)

WARNING! Ignoring the following instructions can cause physical injury or death,
or damage to the equipment.
Support the top and
bottom of the module
while removing!
max 50 mm
Lift the module by the upper part
only using the lifting hole(s) at the
top!
Maintenance
Use extreme caution when maneuvering an inverter, supply or filter module
that runs on wheels. The modules are heavy and have a high center of gravity.
They topple over easily if handled carelessly.
Do not use the ramp which is supplied with the drive with heights over 50 mm
(1.97 in) (the standard plinth height of ABB cabinets). The ramp is designed for
a plinth height of 50 mm (1.97 in).
Do not tilt!
Mind your fingers! Keep fingers away from the
edges of the front flange of the module!
ACQ800-37 Hardware Manual
Extend the support legs outside the
cabinet!