Installation Safety; Input And Output Functionality And Connections; J1 Power Terminal Block; J2 Power Terminal Block - BFT CSB-BR Installation And Operation Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 15

4. INSTALLATION SAFETY

In order to reach the level of safety required by current regulations, follow these prescriptions carefully.
1) Make all the connections in the terminal block after carefully reading the instructions given in this manual and observing the general
rules and technical standards governing electrical systems.
2) Upstream from the control board, fi t an omnipole circuit breaker with a contact gap of at least 3 mm.
3) Install a circuit breaker device with a threshold of 30 mA, if not present.
4) Check the eff ectiveness of the grounding system and connect to it all the parts of the automation fi tted with a terminal or grounding
cable.
5) Fit at least one external warning device, such as a traffi c light or fl ashing light, along with a warning or danger sign.
6) Fit all the safety devices required by the type of installation, taking into consideration the risks that can happen.
7) Separate the power lines (min. sect. 1.5 mm

5. INPUT AND OUTPUT FUNCTIONALITY AND CONNECTIONS

L N E
OUT24
Output 24Vac, 1A max
24 Vac
OUT2
Programmable potential-free relay output, max. 500mA 24 Vac/dc (set by parameter o2 - level 2)
OUT3
Programmable potential-free relay output, max. 500mA 24 Vac/dc (set by parameter o3 - level 2)
OUT4
Programmable potential-free relay output, max. 500mA 24 Vac/dc (set byparameter o4 - level 2)
2nd
CH
2nd CH RX
RX
N.O. output of the 2nd radio receiver channel, for both installed and plug-in radio
16 -
CSB-BR
2
) from the low-voltage signal lines (min. sect. 0.5 mm
J1
5.1
LINE 230V
230V 50/60Hz power supply with MOV internal protection and 6.3A T fuse (5x20).
Connect the phase and neutral as shown. It is recommended to use a cable type H07RN-F 2x1.5+E. Connect the
yellow/green wire of the power supply mains to the earth terminal of the appliance.
J2
5.2
CAP NOT CONNECTED HERE
= FLASHING LIGHT: 230Vac; 40W max.
J4
5.3
OUTPUTS/ACCESSORIES TERMINAL BLOCK
OUT1 (arm lights, if present)
Triac output. 24Vac, 500mA max
POWER TERMINAL BLOCK
POWER TERMINAL BLOCK
2
) in the ducts.

Advertisement

Table of Contents
loading

Table of Contents