Factors Affecting Welding Results; Danger From Shielding Gas Cylinders - Fronius MagicWave 190 Operating Instructions Manual

Tig
Hide thumbs Also See for MagicWave 190:
Table of Contents

Advertisement

If the wire-feed unit is attached to a crane holder during welding, always use a suitable,
insulated wirefeeder hoisting attachment (MIG/MAG and TIG devices).
If the device has a carrying strap or handle, this is intended solely for carrying by hand. The
carrying strap is not to be used if transporting with a crane, counterbalanced lift truck or
other mechanical hoist.
All lifting accessories (straps, handles, chains, etc.) used in connection with the device or
its components must be tested regularly (e.g. for mechanical damage, corrosion or chang-
es caused by other environmental factors).
The testing interval and scope of testing must comply with applicable national standards
and directives as a minimum.
Odourless and colourless shielding gas may escape unnoticed if an adapter is used for the
shielding gas connection. Prior to assembly, seal the device-side thread of the adapter for
the shielding gas connection using suitable Teflon tape.
Factors affecting
The following requirements with regard to shielding gas quality must be met if the welding
welding results
system is to operate in a correct and safe manner:
-
-
-
Filters must be used if necessary.
IMPORTANT! There is an increased risk of soiling if ring mains are being used
Danger from
Shielding gas cylinders contain gas under pressure and can explode if damaged. As the
shielding gas cyl-
shielding gas cylinders are part of the welding equipment, they must be handled with the
inders
greatest of care.
Protect shielding gas cylinders containing compressed gas from excessive heat, mechan-
ical impact, slag, naked flames, sparks and arcs.
Mount the shielding gas cylinders vertically and secure according to instructions to prevent
them falling over.
Keep the shielding gas cylinders well away from any welding or other electrical circuits.
Never hang a welding torch on a shielding gas cylinder.
Never touch a shielding gas cylinder with an electrode.
Risk of explosion - never attempt to weld a pressurised shielding gas cylinder.
Only use shielding gas cylinders suitable for the application in hand, along with the correct
and appropriate accessories (regulator, hoses and fittings). Only use shielding gas cylin-
ders and accessories that are in good condition.
Turn your face to one side when opening the valve of a shielding gas cylinder.
Close the shielding gas cylinder valve if no welding is taking place.
If the shielding gas cylinder is not connected, leave the valve cap in place on the cylinder.
The manufacturer's instructions must be observed as well as applicable national and inter-
national regulations for shielding gas cylinders and accessories.
14
Size of solid matter particles < 40 μm
Pressure dew point < -20 °C
Max. oil content < 25 mg/m³

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magicwave 230iTranstig 230i

Table of Contents