2. Output module type CP-A08...-M12-...
2.3.2 Connecting the output module
WARNING
Please observe the maximum permitted string
lengths. In this way you will avoid faults in data
exchange between the output module and the
higher-order system (e.g. field bus node).
Use only the following cables to connect the
modules.
For connection to
Field bus node
with CP connection
Axis interface
type SPC-AIF-...
Powerbox
Type CP-FB-TBOX-
...
Communication takes place via the CP cable and the
operating voltage for the internal electronics of the mo-
dule is also supplied via the CP cable.
The output module is connected directly to the CP con-
nection of the higher-order system (field bus node, axis
interface or Powerbox). Detailed instructions can be
found in the relevant system manual.
CP-A08...-M12 9901b
Max. permitted
Cable type
string length
10 m
- KVI-CP-1-...
or
- KVI-CP-2-...
See manual for the
(can be used as
SPC200 type
drag chain)
P.BE-SPC200-...
See manual for the
higher-order
system
2-13