  • Page 1 Manifold block CPE…-PRS… Operating instructions 8080201 2017-12f [8080203]...
  • Page 2 ............... . . Festo CPE...-PRS 2017-12f...
  • Page 3 CPE...-PRS... Documentation on the product For all available product documentation è www.festo.com/pk English – Manifold block for valve linking module Type CPE...-PRS... Operating parts and connections Connector Protection against incorrect rotation Valve slides Fastening slides Blind plates Fig. 1 Festo CPE...-PRS 2017-12f English...
  • Page 4: Function And Application

    S Compare the specified limit values with your current application. The permissible limit values, e.g. for pressures and temperatures, must not be exceeded. S Also observe the regulations of the trade association, the German Technical Control Board (TÜV), the VDE and relevant national regulations. Festo CPE...-PRS 2017-12f English...
  • Page 5 CPE...-PRS... inwards with a punch (A) as shown in the sketch – Deburr any broken edges – Remove shavings Due to this time-saving work mode, ir­ regular edges occur compared with preci­ Fig. 4 sion processing by machine. Festo CPE...-PRS 2017-12f English...
  • Page 6 2nd detent. Valveslide and valve are then flush against each other. Fig. 7 Warning Only in this way can you prevent non-secured valves from being pushed out when the sub-base is pressurized. Festo CPE...-PRS 2017-12f English...
  • Page 7 Pneumatic Use preferably round connectors of type QS..-... with cylindrical connecting thread. Connect the pneumatic tubing in accordance with the pressurization sketch (compare with Fig. 3). The connecting threads must be sealed (torques è Technical data). Festo CPE...-PRS 2017-12f English...
  • Page 8: Maintenance And Care

    Dismantling and repairs In order to dismantle the CPE valves: Exhaust the CPE...-PRS... Pull the valve slide 2 outwards one notch. Observe here the minimum distance between the valve slide and the mounting surface of the connector 1. Festo CPE...-PRS 2017-12f English...
  • Page 9 2. Loosen the locking screws. 3. Dismantle linked CPE...-PRS-..4. Use a screwdriver to lift up the fastening slides of the individual sub-bases. Fig. 12 Accessories Designation Type Blind plate CPE-...-PRSB Designation signs IBS 6 x 10 Fig. 13 Festo CPE...-PRS 2017-12f English...
  • Page 10: Eliminating Faults

    30 Nm 30 Nm torque for cylindrical connectors Permissible temperature Ambient, medium: –5 °C ... +50 °C range Storage: –20 °C ... +40 °C Materials Housing: Polyamide Fittings: Aluminium Seals: Nitrile rubber Connections: Galvanized steel Fig. 15 Festo CPE...-PRS 2017-12f English...
  • Page 11 CPE...-PRS... Festo CPE...-PRS 2017-12f...
  • Page 12 Copyright: Festo AG & Co. KG Ruiter Straße 82 73734 Esslingen Germany Phone: +49 711 347-0 Fax: +49 711 347-2144 E-mail: Reproduction, distribution or sale of this document or communica­ service_international@festo.com tion of its contents to others without express authorization is prohibited.