1. Input module type CP-E16...-M...-...
1.5 Technical specifications
Technical specifications
Temperature range:
- operation
- storage/transport
Relative humidity
Protection class as per EN
60 529
Plug connector inserted or
fitted with protective cap
Protection against electric
shock as per EN 60204-1 /
IEC 204
Electromagnetic compatibility
- interference emission
- resistance to interference
Digital inputs
- Design
- Logic level:
ON
OFF
- Current consumption
(at 24 V)
(input current from sensor
to input)
- Response delay (at 24 V)
Sensor supply
Electrical isolation
Internal current consumption
of electronic components
1-26
Positive-switching input modules (PNP)
Type CP-E16-M8 and
type CP-E16-M12x2
o
o
-5
C ... + 50
C
o
o
-20
C ... + 70
C
95% non condensing
IP 65
(Protection against direct and indirect contact) by
connecting to a PELV power unit (Protected Extra-Low
Voltage)
Tested as per EN 55011 limit value class B
Tested as per EN 50082-2
16 inputs
as per IEC 1131-2 type 2
inputs
24 V DC
positive-switching
> 11 V
< 5 V
at "logic 1"
typ. 8 mA
typ. 5 ms
max. 0.5 A
(electronic short circuit protection)
None
< 40 mA
Type CP-E16-M12x2-5POL
16 inputs
as per IEC 1131-2 type 2
inputs
24 V DC
negative-switching
≥ 8.6 V
≤ 6 V
at "logic 1"
typ. 6 mA
typ. 3 ms
max. 90 mA
CP-E16...-M... 9901b