Technical Specifications - Festo CP-E16 Series Manual

Compact performance cp modules
Hide thumbs Also See for CP-E16 Series:
Table of Contents

Advertisement

2. Output module type CP-A08...-M12-...

2.5 Technical specifications

Technical specifications

Temperature range:
- operation
- storage/transport
Relative humidity
Protection class as per EN 60 529
Plug connector inserted or fitted with
protective cap
Protection against electric shock as
per EN 60204-1 / IEC 204
Electromagnetic compatibility
- interference emission
- resistance to interference
Load voltage connection
- rated value
(protected against incorrect polarity)
- tolerance
- residual ripple
- Isolation resistance
- internal current consumption of
electronic components
Digital outputs
- design
- loading per digital output
- Electronic fuse
(short circuit, overload)
trigger current
response time
2-20
Positive-switching output modules
Type CP-A08-M12 and type CP-A08-M12-5POL
o
o
-5
C ... + 50
C
o
o
-20
C ... + 70
C
95% non condensing
IP 65
(Protection against direct and indirect contact) by
connecting to a PELV power unit (Protected
Extra-Low Voltage)
Tested as per EN 55011 limit value class B
Tested as per EN 50082-2
Electrically isolated load voltage via additional
M18 plug connector.
24 V
± 25%
4 Vpp (within tolerance)
500 V
< 40 mA
8 outputs
as per IEC 1131-2; 24 V DC
positive switching
0.5 A
min. 750 mA
max. 1.5 ms
CP-A08...-M12 9901b