Set Subnet Mask
Set Gateway IP
Set DNS Server Address @0DNxxxx\r
Set NTP Server Address @0NPxxxx\r
Enter NTP Cycle Time
Set Syslog Server
Network Settings
Address
Set IP Control Port
Number
Authentication On/Off
Create Operator
Password
Create Observer
Password
Logout of IP Control
20
Control Commands
(Host → DN-700R)
CONTENTS
@0SMxxxx\r
@0GWxxxx\r
@0NChhmm\r
@0Slxxxx\r
@0IpNNNNN\r
@0IaNN\r
@0OPxxxx\r
@0Opxxxx\r
@0LO\r
CODE
If a static IP address is assigned to DN-700R,
sets the subnet mask, where xxxx stands for the
subnet mask number (omitting any periods)
Note: DN-700R will automatically reboot after
this command is executed
If a static IP address is assigned to DN-700R,
sets the Gateway IP address, where xxxx stands
for the IP address (omitting periods)
Note: DN-700R will automatically reboot after
this command is executed
If a static IP address is assigned to DN-700R,
sets the DNS server address, where xxxx stands
for the address number (omitting periods)
DN-700R will automatically reboot after this
command is executed
Sets the NTP server address, where xxxx stands
for the address number (omitting periods); to
turn NTP off, enter DISABLE00000 for the xxxx
variable
Enters the NTP cycle time, where hhmm (the
cycle time in hours and minutes) = 0015–2400
Note: The cycle time can only be entered in
fifteen minute increments
Sets the syslog server address, where xxxx
stands for the server address (omitting periods);
to turn syslog off, enter DISABLE00000 for the
xxxx variable
Sets the IP control port number, where NNNNN
(the number) = 00000–65535
Note: DN-700R will automatically reboot after
this command is executed
Sets whether password authentication is
required for IP control, where NN (the setting) =
00 (required) or 01 (not required)
Note: DN-700R will automatically reboot after
this command is executed
Sets the operator password for the web remote
control, where xxxx stands for a password of 6–
12 characters
See
Appendix > Acceptable Characters for
Serial Communication
characters can be used in the password
Sets the observer password for the web remote
control, where xxxx stands for a password of 6–
12 characters
See
Appendix > Acceptable Characters for
Serial Communication
characters can be used in the password
Logout of web remote control