Supplementary Maintenance - Kalor Paola 13 User Manual

Insert air stoves
Table of Contents

Advertisement

11.9 Cleaning the clearing system
Until a reasonable experience is acquired regarding the operating conditions, it is advisable to perform this maintenance
on at least a monthly basis.
• Remove the electrical feed cable;
• Remove the cap from the T-joint and proceed with the cleaning of the ducts. If necessary, at least for the first few times,
call in qualified personnel;
• Carefully clean the smoke discharge system: for this, contact a professional chimney sweep;
• Once a year clean the dust, cobwebs, etc. from the zone behind the internal covering panels, paying particular attention
to the fans.
11.10 Cleaning the fans
The insert is furnished with fans (environmental and smoke) positioned at the rear and below the insert.
Eventual deposits of dust or ash on the blades of the fan can cause an imbalance in the fans leading to noisy performance.
It is, therefore, necessary to clean the fans at least once a year.
Since said operation requires dismantling several parts of the insert, have the fans cleaned only by our Technical Assistance
Centre.

12.0 Supplementary maintenance

(to be done every 6 months or after 1000 kg burnt
pellets)
12.1 Cleaning of the combustion chamber
• Open the door and remove the hearth, the brazier and
the ash box;
• Remove the flap holding the inner wall and pull
this and the two side walls out with due caution
(Pict. 20);
• Remove the flame shield. Let it run towards the door,
remove the support flaps and lower it until you can pull
it out (Pict. 21);
• Spray some suitable loosening product on the screws
fastening the upper and lower panels of the combustion
chamber. Wait until the screws are loosened and remove
them using a suitable tool. Remove the panels;
• Use a paddle or an aspirator ro remove any eventual ash
rests or incrustations. Remove in correct order all the
removed parts. Remember to lubricate the scres fasten-
ing the panels.
12.2 Insert back side
• With due caution lift the insert a bit and remove it from
the check pin of 5 mm.;
• Pull the insert out of the fireplace. You need four of you
at the four sides of the insert. Lift it by hand and put it
on a level surface;
• Using a brush or an aspirator remove any eventual ash
or dust rests. Installa the insert again: Place it on the
support and push it slowly until it reaches the apposite
check pin;
• Check that the flue system lies perfectly in the T pipe.
Pict. 20: how to remove the sides
Pict. 21: how to remove the flame protection
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Chiara 15

Table of Contents