WARNING: Battery posts, terminals, and related accessories contain lead and lead compounds, chemicals
known to the State of California to cause cancer and reproductive harm, and during charging,
strong inorganic acid mists containing sulfuric acid are involved, a chemical known to the
State of California to cause cancer. Wash hands after handling. For more information go to
www.P65Warnings.ca.gov.
WARNING: Batteries emit hydrogen and oxygen gas.
-Keep sparks and open flame away. Do not smoke near the machine.
-Charge batteries in a well-ventilated area with the battery compartment open.
WARNING: Do not wear jewelry when working near moving or electrical components.
CAUTION: Remove the batteries and get assistance before lifting the machine manually.
CAUTION: Park and service the machine on a level surface and remove the key.
CAUTION: Always wear protective clothing, gloves and goggles when handling and charging batteries.
NOTE:
All repairs must be performed by a qualified service technician using approved replacement parts.
NOTE:
Batteries designed for automotive or marine and RV use are not suited for use in floor scrubbers.
SELECTION
The machine requires two 12 VDC Lead Acid or AGM Deep Cycle batteries designed for floor scrubber use
with the following maximum dimensions:
Width:
Length:
Height:
INSTALLATION
1.
Open the recovery tank.
2.
Use a lifting device capable of transferring the
batteries safely.
3.
Slide the batteries forward.
4.
Connect the batteries in series, to obtain overall
voltage of 24V on the lugs.
5.
Fully charge the batteries before using the machine.
RETURN TO
TABLE OF
CONTENTS
4. BATTERIES
7 1/8 in (181 mm)
12 15/16 in (264 mm)
10 5/8 in (295 mm)
6