OFF-BOARD CHARGER

WARNING: Battery posts, terminals, and related accessories contain lead and lead compounds, chemicals
known to the State of California to cause cancer and reproductive harm, and during charging,
strong inorganic acid mists containing sulfuric acid are involved, a chemical known to the
State of California to cause cancer. Wash hands after handling. For more information go to
www.P65Warnings.ca.gov.
WARNING: Do not plug in charger cable if wall cord or battery harness is damaged.
NOTE: Ensure battery charging and storage locations comply with OSHA and any governing agencies'
standards based on your particular location and application.
Set the Battery Type switch to match the battery configuration of the machine.
Up for Lead Acid batteries.
Down for sealed, maintenance-free AGM batteries
1. Connect the charger to the wall outlet.
2. Connect the red plug (pictured below) to the battery harness below the control panel at the rear of the
machine.
Off-board status LEDs:
Primary (green) LED:
Blinking slowly: Batteries are below 80% of full charge.
Blinking rapidly: Batteries are above 80% of full charge.
Solid: Batteries are fully charged.
Fault (red) LED:
See the charger manual for fault information.