Pacific S-20 Parts & Operating Manual page 13

11 gallon autoscrubber
Hide thumbs Also See for S-20:
Table of Contents

Advertisement

SETTING THE CHARGER ON MACHINES PURCHASED WITHOUT BATTERIES
Configure the charging profile to the type of batteries installed on the machine. Switch banks SW1 and SW2
are located behind the label on the lower right corner of the charger next to the green LED.
SW2: Set the charge current according to the battery amp hour rate
(Reference CHARGE CURRENT AND BATTERY AMP
HOURS table below).
DP2
DP1
CHARGING CURRENT
ON
ON
15A
ON
OFF
20A
OFF
ON
25A
OFF
OFF
25A
SW1: Set the current profile according to the battery installed.
DP2
DP1
CHARGING CURRENT
OFF
ON
Lead-Acid (Wet) Batteries
OFF
OFF
AGM FULLRIVER
ON
OFF
AGM DISCOVER
ON
ON
Gel
CHARGING CURRENT
15A
20A
25A
RETURN TO
TABLE OF
CONTENTS
BATTERY AMP HOUR RANGE
(5h)
100-150 Ah
120-195 Ah
180-258 Ah
12
(20h)
130-180 Ah
150-240 Ah
220-315 Ah

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-20hdS-24xm