CLEANING THE BATTERYSHIELD
WARNING: Battery posts, terminals, and related accessories contain lead and lead compounds, chemicals
known to the State of California to cause cancer and reproductive harm, and during charging,
strong inorganic acid mists containing sulfuric acid are involved, a chemical known to the
State of California to cause cancer. Wash hands after handling. For more information go to
www.P65Warnings.ca.gov.
WARNING: Do not wear jewelry when working near moving or electrical components.
WARNING: Batteries emit hydrogen and oxygen gas.
-Keep sparks and open flame away. Do not smoke near the machine.
-Charge batteries in a well-ventilated area with the battery compartment open.
CAUTION: Always wear protective clothing, gloves and goggles when handling and charging batteries.
NOTE: Failure to clean the HydroLink
and will reduce battery life.
1.
Remove the cap with the black sensor module, being careful not
to damage the yellow floats. Do not remove the black module from
the cap assembly.
2.
Thoroughly wipe the clear light pipe next to the middle yellow
float, paying attention to the tip of the pipe.
3.
While the cap is still removed, cycle the key and verify the LED
stays on steady. Turn the key off.
4.
Carefully align the cap and press it firmly onto the battery
making sure it is fully seated.
5.
Complete the battery servicing procedures above, cycle the key,
and verify the light stays off.
6.
The machine is ready for use.
RETURN TO
TABLE OF
CONTENTS
SENSOR LIGHT PIPE
®
light pipe will limit the BatteryShield's
®
10
ability to read the water level
®

Hide quick links: