5. Place the batteries in their compartment.
6. Connect the batteries' connector (2) to the machine's connector (1).
7. Reassemble the recovery tank, vacuum plug and squeegee hose.

3. CONNECTING THE BATTERY CHARGER

The battery charger's connector fits into the battery connector (2) located under
the recovery tank.

4. CHARGING THE BATTERIES

NEVER ALLOW THE BATTERIES TO RUN COMPLETELY DOWN, re-
charge them within a few minutes after the battery indicator starts blinking. Never
leave the batteries completely discharged, even if the machine is not being
used.
WARNING! When charging the batteries, follow all the instructions
provided with this manual and the battery charger. Trained staff must
carry out the installation and maintenance operations.
WARNING! Fire Danger: Lead acid batteries generate gases that
can cause an explosion. Keep sparks and flames away from batteries.
NO SMOKING!
WARNING! To prevent an explosion, charge the batteries only in an
area with good ventilation.
WARNING! Always wear eye protection and protective clothing
when working near batteries.
When charging the batteries, keep the recovery tank lifted by supporting the prop
as shown in the figure.
Turn the key to the OFF position. Connect the DC connector on the charger to the
DC battery connector. Connect the AC charger plug to a receptacle that has the
correct voltage and frequency for your charger. Make sure the receptacle is con-
nected to the electrical ground.