4.4.2.6 Needle XY Offset
To calculate the needle XY offset (Figure 4-13):
1.
Click on the Next button to start Offsets for Dot Type 1.
2.
Click on the Yes to reteach substrate corners on the mini service station on the back of
Conveyor Rail 2.
a. Use the position controls to move the camera crosshairs to the upper left substrate
corner and click on Teach.
b. Use the position controls to move the camera crosshairs to the lower right substrate
corner and click on Teach.
3.
Move the camera crosshairs to the dot locations and click on Teach.
4.
Click on Done when finished with Dot Type 1 Vertical.
5.
Repeat steps 1, 3 and 4 for all dot types in CW (clockwise) tilt direction.
6.
Repeat steps 1, 3 and 4 for all dot types in CCW (counterclockwise) tilt direction.
You will return to the Machine Setup Window.
7.
Click on Exit in the Machine Setup Window when all offsets are complete.
Operation

Figure 4-13 Alignment Dot 1 Dispensing Valve 1

23