Figure 4-9 Needle To Height Sensor Z Offset; Figure 4-10 Needle To Height Sensor Z Offset Summary - Nordson ASYMTEK Spectrum Series Owner's Manual

Single-axis automatic tilt mechanism
Table of Contents

Advertisement

4.4.2.4 Needle Z Offset
To teach needle to height sensor Z offset (Figure 4-9 and Figure 4-10):
1.
Select the Teach Center Method.
2.
Use the position controls to move the camera crosshairs to the teaching point(s) on the
tactile sensor and click on Teach.
3.
Click on Done when finished.
The machine will now calculate the
offset measurements for the vertical
and the front/rear or left/right tilts.
The tilt direction is specified in the
Setup Valves window (Figure 3-8).
The Z Offset Summary will appear
(Figure 4-10).
4.
Click on Front to see the offset values
for the front tilt.
5.
Click on Rear to see the offset values
for the rear tilt.
6.
Click on OK to close the summary.
NOTE
20

Figure 4-9 Needle to Height Sensor Z Offset

In this example, the left and right tilt values are grayed out. If the tilt direction
selected in Setup Valves is left/right, these values would be active and the front
and rear values would be grayed out.
Figure 4-10 Needle to Height Sensor Z Offset
Summary
Operation

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spectrum s-9 seriesSpectrum s2-9 series

Table of Contents