4.3

Dot and Line Parameters for Tilt

Prior to running valve offsets and creating a program, you must define dot and line parameters. Dot and
line parameters control the size and accuracy of dot or line dispensing.
4.3.1

Dot Parameters

To edit dot parameters:
1.
In the Fluidmove Main Window, select Teach a Program.
The Programming Window opens.
2.
Select Edit > Dot Parameters from the drop-down menu.
The Dot Parameters window opens.
3.
Select the Valve Tilt tab (Figure 4-1).
4.
Select the tilt direction for each dot that will be used in the program.
The dispense gaps for lines and dots are set in the Dot Parameters. See
Parameters.
Select None in the Use Offset to Disp Gaps pull down window.
5.
None will force the user to run an offset for each dispense gap.
If Dot Type 1 is selected, the offsets created by Dot Type 1 will be used for all dot types.
This can result in dispense inaccuracies due to the different dispense gaps. If Dot Type 2
is selected, the offsets created by Dot Type 2 will be used for all dot types, etc.
6.
Click on Apply and then on OK to close the window.
7.
Click on
12
to return to the Fluidmove Main Menu.

Figure 4-1 Dot Parameters

4.3.2 Line