Electrodes location of the process unit
Faulty registration
Step
Registration rear actuator
1
coming off
2
Laser unit failure
3
Main PCB failure
Fig. 2-13
<User Check>
• Check whether appropriate paper type is selected on the
driver.
• Install the latest main firmware.
Cause
Reattach the registration rear actuator.
Replace the laser unit.
Replace the main PCB ASSY.
2-65
Remedy