3. ERROR INDICATIONS

This machine includes a self-diagnosis function. If the machine does not work normally it judges
that an error has occurred, and indicates the corresponding error message on the LCD, which
in turn helps the service personnel to quickly find out the problem.
3.1 Error Codes
The shaded errors hardly occur under normal use. They may be caused by noise around the
installation site, variation in power supply voltage, or software failure.
Error
Codes
0101 ---
ASIC error or motor driver error
0102
occurred.
Cannot detect the synchronized signal
of the paper feed motor. The speed of
0201
the paper feed motor does not stabilize
within the specified time.
0202 ---
0203 ---
Cannot detect the lock signal of the
0300
polygon motor for the laser unit.
(second time)
Cannot detect the lock signal of the
0305
polygon motor for the laser unit. (first time)
0401 BD sensor failure (second time)
0402 ---
0405 BD sensor failure (first time)
The center thermistor of the fuser unit
0501
has not reached the specified
temperature within the specified time.
The center thermistor of the fuser unit has
not reached the specified temperature
0502
within the specified time after it was
heated normally to the certain level.
The center thermistor of the fuser unit
0503
detected a temperature higher than the
specified value.
After the heat unit was heated normally, the
0504
center thermistor of the fuser unit detected a
temperature lower than the specified value.
The center thermistor of the fuser unit
0505
detected a temperature rise greater than
the specified value within the specified time.
The center thermistor of the fuser unit
0506
detected a temperature fall greater than the
specified value within the specified time.
Temperature of the end part didn't rise by 1
0508
°C when the fuser unit heater was turned ON.
Description
Refer
Error
to:
Codes
The hardware detected a temperature
050A
error through the center thermistor or
the side thermistor of the fuser unit.
When the center thermistor of the fuser unit
was lower than the idle temperature, the
2-33
050B
side thermistor detected a temperature
higher than the specified temperature.
When the center thermistor of the fuser unit
was higher than the idle temperature, the
2-33
050C
side thermistor detected a temperature
lower than the specified temperature.
050D ---
2-33
050F ---
2-33
0800 ---
Detected irregular power supply for
2-34
0900
more than 100 times.
0A01 ---
2-34
0A02 Detected a fan failure.
2-35
0A03 ---
An error occurred in the high-voltage
2-35
0B01
power supply PCB ASSY while
operating.
An error occurred in the high-voltage
2-35
0B02
power supply PCB ASSY when the
machine was in the ready state.
2-35
0C00 ---
2-35
0D01 ---
2-35
0D02 ---
2-35
0D03 ---