Electrical Interface; Inputs; Outputs; Relay Outputs - Christie ACT User Manual

Table of Contents

Advertisement

6.3

Electrical Interface

6.3.1 Inputs

Parameter
Input voltage range
Isolation voltage
ON voltage level
OFF voltage level
Min. ON time
Pull-up current

6.3.2 Outputs

Relay Outputs

Parameter
Small relay contact ratings (continuous A)
Small relay contact ratings
Large relay contact ratings (continuous A)
Large relay contact ratings (resistive)
Wire size accepted - Clip terminals
Christie ACT User Manual
020-100129-05 Rev. 1 (02-2010)
Figure 6-2 Opto-Isolated Inputs
Symbol
V
max
V
iso
V
H
V
L
t
min
I
PU
Only Qualified Electricians should connect primary voltages.
Figure 6-3 Relay Outputs
Min.
Norm.
0
1000
3
1
10
Pin
Symbol
Min.
I
-
CMax
1 to 12
V
-
CMax
I
0.1
CMax
13 & 14
V
CMax
Gauge
28
Section 6: Specifications
Max.
Unit
30
V
V
30
V
1
V
ms
mA
Nom.
Max.
Unit
-
1
A
-
220
V
DC
8
A
240
V
AC
-
16
AWG
6-3