Download Print this page

Specifications - Banner DX99N9X1S2N0M2X0D2 Manual

Surecross dx99 flex power node (metal housing)

Advertisement

SureCross DX99 FlexPower Node (Metal Housing)

Specifications

1
Radio Range
900 MHz, 150 mW: Up to 4.8 km (3 miles)
2.4 GHz, 65 mW: Up to 3.2 km (2 miles)
Minimum Separation Distance
900 MHz (150 mW): 2 m (6 ft)
2.4 GHz (65 mW): 0.3 m (1 ft)
Transmit Power
900 MHz, 150 mW: 21 dBm (150 mW) conducted
2.4 GHz, 65 mW: 18 dBm (65 mW) conducted, less than or equal to 20
dBm (100 mW) EIRP
900 MHz Compliance (150 mW)
FCC ID TGUDX80 - This device complies with FCC Part 15, Subpart C,
15.247
IC: 7044A-DX8009
2.4 GHz Compliance
FCC ID UE300DX80-2400 - This device complies with FCC Part 15,
Subpart C, 15.247
ETSI/EN: In accordance with EN 300 328: V1.7.1 (2006-05)
IC: 7044A-DX8024
Spread Spectrum Technology
FHSS (Frequency Hopping Spread Spectrum)
Link Timeout
Gateway: Configurable via User Configuration Tool (UCT) software
Node: Defined by Gateway
Discrete Inputs
Rating: See control drawing
Sample/Report Rates: DIP switch configurable
Discrete Input ON Condition
PNP: Greater than 8 V
NPN: Less than 0.7 V
Discrete Input OFF Condition (DX99 Models)
PNP: Less than 4.5 V
NPN: Greater than 2.2 V or open
Analog Input Rating (mA Models)
Rating for 4 to 20 mA models: 24 mA
Impedance: Approx. 20 Ohms
Analog Input 1 Sample/Report Rates: DIP switch configurable
Analog Input 2 Sample/Report Rates: 1 second / 16 seconds
Accuracy: 0.1% of full scale +0.01% per °C
Resolution: 12-bit
Analog Input Rating (V Models)
Rating for 0 to 10V models: 10 V
Impedance: Approx. 20 Ohms
Analog Input 1 Sample/Report Rates: DIP switch configurable
Analog Input 2 Sample/Report Rates: 1 second / 16 seconds
Accuracy: 0.25% of full scale +0.01% per °C
Resolution: 12-bit
To verify the analog input's impedance, use an Ohm meter
to measure the resistance between the analog input
terminal (AIx) and the ground (GND) terminal.
Metal Housing Dimensions
The metal housing is used for the DX99...D models.
1 Radio range is with the 2 dB antenna that ships with the product. High-gain antennas are available, but the range depends on the environment and line of
sight. To determine the range of your wireless network, perform a Site Survey.
2 Refer to the
SureCross Wireless I/O Networks Instruction Manual
3 Operating the devices at the maximum operating conditions for extended periods can shorten the life of the device.
P/N 142497 Rev. L
Supply Voltage
3.6 V dc low power option from an internal battery
Power Consumption
Consumption: Application dependant
Housing
Glass and cast aluminium w/ chromating and chemically resistant paint
(outside only)
Antenna Connection
Ext. Reverse Polarity SMA, 50 Ohms
Max Tightening Torque: 0.45 N·m (4 lbf·in)
Interface
Indicators: Two bi-color LEDs
Buttons: Two
Display: Six character LCD
Wiring Access
Two 1/2-inch NPT ports, one 3/4-inch NPT port (internal threads)
Environmental Rating
IEC IP68
Operating Conditions
−40 °C to +65 °C (−40 °F to +149 °F) (Electronics); −20 °C to +80
°C (−4 °F to +176 °F) (LCD)
95% maximum relative humidity (non-condensing)
Radiated Immunity: 10 V/m, 80-2700 MHz (EN61000-6-2)
Shock and Vibration
IEC 68-2-6 and IEC 68-2-27
Shock: 30g, 11 millisecond half sine wave, 18 shocks
Vibration: 0.5 mm p-p, 10 to 60 Hz
Certifications
Special Conditions for Safe Use imposed by Intrinsic Safety Certificate
LCIE 08 ATEX 6098 X: Ambient temperature range is –40 to 70 °C.
SureCross
Intrinsically Safe certified equipment or simple apparatus as defined by
EN 60079-11. All connected equipment must comply with the Entity
Parameters (Safety Parameters) listed in the
141513). The device must only use a lithium battery manufactured by
XENO, type XL-205F.
(p/n 132607) for installation and waterproofing instructions.
www.bannerengineering.com - Tel: +1-763-544-3164
2
3
CSA: Class I, Division 1, Groups A, B, C, D; Class II, Division 1,
Groups E, F, G; Class III, Division 1 (Ex ia IIC T4 / AEx ia IIC T4)
Certificate: 2008243
LCIE/ATEX: Zone 0 (Category 1G) and 20 (Category 1D),
Temperature Class T4 (II 1 GD / Ex ia IIC T4 / Ex iaD 20 IP68 T82°C)
Certificate: LCIE 08 ATEX 6098 X
®
DX99 FlexPower devices can only be connected to
Control Drawings
(p/n
11

Advertisement

loading