Banner ES-UA-5A Manual

Banner ES-UA-5A Manual

Emergency stop safety modules
Hide thumbs Also See for ES-UA-5A:

Advertisement

Quick Links

WARNING . . .
This Emergency Stop Safety Module is not a point-of-operation guarding device, as defined by OSHA regulations. It is
necessary to install point-of-operation guarding devices, such as safety light curtains and/or hard guards, to protect personnel
from hazardous machinery. Failure to install point-of-operation guards on hazardous machinery can result in a dangerous
condition which could lead to serious injury or death.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Emergency Stop Safety Modules
Model ES-UA-5A for 12-24V dc/115V ac operation; Model ES-VA-5A for 12-24V dc/230V ac operation
EMERGENCY STOP DEVICE
• Monitors one dual-channel normally closed Emergency Stop switch circuit for
a contact failure or wiring fault
• Four output switching channels for connection to control-reliable power interrupt
circuits
• Auto reset or monitored manual reset
• Design complies with standards UL 991, EN 418, and EN 954-1 (Category 4)
• For use in functional stop category 0 applications per NFPA 79 and
IEC/EN 60204-1
• 6 amp safety output contacts
• Plug-in terminal blocks
• 12-24V dc/115V ac or 12-24V dc/230V ac operation
• External Device Monitoring (one-channel EDM)
29YL
Features

Advertisement

Table of Contents
loading

Summary of Contents for Banner ES-UA-5A

  • Page 1 Emergency Stop Safety Modules Model ES-UA-5A for 12-24V dc/115V ac operation; Model ES-VA-5A for 12-24V dc/230V ac operation EMERGENCY STOP DEVICE 29YL Features • Monitors one dual-channel normally closed Emergency Stop switch circuit for a contact failure or wiring fault •...
  • Page 2 Banner Engineering Corp. has made every effort to provide complete application, installation, operation, and maintenance instructions. In addition, any questions regarding the use or installation of this Banner Emergency Stop Safety Module should be directed to the factory applications department at the telephone numbers or address shown on back cover.
  • Page 3 As indicated in Figures 2 and 3, the models ES-UA-5A and ES-VA-5A E-Stop Safety Modules are designed to monitor a 1-channel or 2-channel E-stop switch. A 2-channel E-stop switch has two electrically isolated contacts.
  • Page 4: Channel Input

    E-Stop Safety Module – Models ES-UA-5A and ES-VA-5A E-Stop Switch Requirements WARNING . . . 1-Channel Input As shown in Figures 4, 5, and 6, the E-stop switch must provide contacts which are If a 1-channel E-stop closed when the switch is in the “armed” position. Once activated, the E-stop switch must...
  • Page 5: Mechanical Installation

    Reset of the Safety Modules is not possible if one switch fails to open, or if a short circuit between the safety switches occurs. Please contact the Banner Factory Applications Group at the numbers listed on the last page to discuss your intended use.
  • Page 6: Auto Reset

    E-Stop Safety Module – Models ES-UA-5A and ES-VA-5A Auto Reset Manual Reset For power connection For power connection see Figure 6. see Figure 6. E-Stop Switch E-Stop Switch ES-UA-5A ES-UA-5A 12-24V dc/115V ac 12-24V dc/115V ac ES-VA-5A ES-VA-5A 12-24V dc/230V ac...
  • Page 7 E-Stop Safety Module – Models ES-UA-5A and ES-VA-5A Auto Reset Manual Reset For power connection For power connection see Figure 6. see Figure 6. ES-UA-5A ES-UA-5A 12-24V dc/115V ac 12-24V dc/115V ac ES-VA-5A ES-VA-5A 12-24V dc/230V ac 12-24V dc/230V ac...
  • Page 8: Reset Switch Location

    Automatic Reset Mode WARNING . . . Reset Model ES-UA-5A or ES-VA-5A may be used also with automatic reset. If no MSC-monitor Routine Required contacts are monitored, a jumper must be installed between terminals S31 and S32 (see Figures 4 and 5). The E-Stop Safety Module will reset (and the outputs energize) as soon U.S.
  • Page 9: Initial Checkout Procedure

    E-Stop Safety Module – Models ES-UA-5A and ES-VA-5A Initial Checkout Procedure CAUTION . . . Disconnect Power Prior to Checkout Checkout procedure: Before performing the initial checkout 1. Remove power from the machine control elements. procedure, make certain all power 2.
  • Page 10: Periodic Checkout Procedure

    1. Contact the Banner Factory Application Engineering Group at the address or at the If the Module is not immediately numbers listed at the bottom of the back page. They will attempt to troubleshoot the replaced or repaired, multiple system from your description of the problem.
  • Page 11: Input Requirements

    E-Stop Safety Module – Models ES-UA-5A and ES-VA-5A Specifications Supply Voltage and Current A1-A: 115V ac (Model ES-UA-5A) or 230V ac (model ES-VA-5A), ± 15%; 50/60Hz B1-B: 12-24V dc, ± 15%, 10% max. ripple Power consumption: approx. 4W/7VA Supply Protection Circuitry...
  • Page 12: Troubleshooting

    This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied.