The SureCross
wireless system is a radio frequency network with integrated I/O that can operate in most environments
and eliminate the need for wiring runs. DX99 wireless networks are formed around a Gateway, which acts as the wireless
network master device, and one or more Intrinsically Safe Nodes.
For additional information, updated documentation, and accessories, refer to Banner Engineering's website,
www.bannerengineering.com/surecross.
Model
DX99N9X1S2N0M2X0D2
DX99N2X1S2N0M2X0D2
DX99N9X1S2N0M2X0D1
DX99N2X1S2N0M2X0D1
Model
DX99N9X1S2N0V2X0D2
DX99N2X1S2N0V2X0D2
DX99N9X1S2N0V2X0D1
DX99N2X1S2N0V2X0D1
Internal antenna models are also available. For more information, contact your local Banner Engineering Corp.
representative. Integrated battery models are also available without batteries. If you purchase a model without the
battery, Banner Engineering recommends using the XENO XL-205F battery or equivalent. For DX99 models, only a XENO
XL-205F battery is certified.
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to
serious injury or death. This device does not include the self-checking redundant circuitry necessary
to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an
energized or de-energized sensor output condition.
Original Document
142497 Rev. L
Wireless industrial I/O device with two selectable discrete inputs and two
analog inputs
®
FlexPower
technology driven by one lithium primary battery integrated
into the housing
DIP switches for user configuration
Frequency Hopping Spread Spectrum (FHSS) technology and Time
Division Multiple Access (TDMA) control architecture ensure reliable data
delivery within the unlicensed Industrial, Scientific, and Medical (ISM)
band
Transceivers provide bidirectional communication between the Gateway
and Node, including fully acknowledged data transmission
Lost RF links are detected and relevant outputs set to user-defined
conditions
DX99 Metal housings are certified for use in Class I, Division 1, Groups A,
B, C, D; Class II, Division 1, Groups E, F, G; Class III, Division 1; and
Zone 0 (Category 1G) and Zone 20 (Category 1D) when properly installed
in accordance with the National Electrical Code, the Canadian Electrical
Code, or applicable local codes/regulations
Frequency
Boost Voltage
900 MHz ISM Band
2.4 GHz ISM Band
900 MHz ISM Band
2.4 GHz ISM Band
Frequency
Boost Voltage
900 MHz ISM Band
2.4 GHz ISM Band
900 MHz ISM Band
2.4 GHz ISM Band
30 December 2014
I/O
Discrete Mode
18 V
Inputs: Two selectable discrete
Switch Power: Two, Configurable
Analog Mode
Inputs: Two selectable discrete, two 0 to 20 mA
10 V
analog
Switch Power: One, Configurable
I/O
Discrete Mode
18 V
Inputs: Two selectable discrete
Switch Power: Two, Configurable
Analog Mode
Inputs: Two selectable discrete, two 0 to 10V
10 V
analog
Switch Power: One, Configurable
142497

Advertisement

loading

Summary of Contents for Banner DX99N9X1S2N0M2X0D2

  • Page 1 Internal antenna models are also available. For more information, contact your local Banner Engineering Corp. representative. Integrated battery models are also available without batteries. If you purchase a model without the battery, Banner Engineering recommends using the XENO XL-205F battery or equivalent. For DX99 models, only a XENO XL-205F battery is certified.
  • Page 2: Setting Up Your Wireless Network

    Download the most recent revisions of the UCT software from Banner Engineering's website: http://www.bannerengineering.com/wireless. The UCT requires a special USB to RS-485 (model number BWA-UCT-900 for 1 Watt radios, BWA-HW-006 can be used for all other radios) converter cable to pass information between your computer and the Gateway.
  • Page 3 SureCross DX99 FlexPower Node (Metal Housing) DIP Switch Settings Switches Device Settings Rotary dial address mode OFF* Extended address mode Analog Configuration OFF* Discrete Configuration * Default configuration Address Mode The SureCross wireless devices may use one of two types of addressing modes: rotary dial addressing or extended addressing.
  • Page 4 SureCross DX99 FlexPower Node (Metal Housing) Analog IN 2, Discrete 1, and Discrete 2 are not powered from switched power terminals. In this configuration, SP2 is disabled. If you need SP2, contact the factory. * Default positions Discrete Configuration - Switch 2 ON (10V and 18V Boost Models) The discrete configuration matches the switch power outputs (SP1, SP2) with the discrete inputs.
  • Page 5 SureCross DX99 FlexPower Node (Metal Housing) Analog Configuration, Switch 2 OFF DIP Switches Descriptions Sample/Report Rate 15 minutes Sample/Report Rate 30 minutes Modbus or UCT configured (overrides DIP switches) Analog IN 2, Discrete 1, and Discrete 2 are not powered from switched power terminals. In this configuration, SP2 is disabled.
  • Page 6: Modbus Register Table

    SureCross DX99 FlexPower Node (Metal Housing) 2.4 GHz 65 mW radios: 1 foot 900 MHz 150 mW radios: 6 feet 900 MHz 1 Watt radios: 15 feet LED 1 LED 2 Node Status Flashing green Radio Link Ok Flashing red Flashing red Device Error Flashing red, 1 per 3 sec...
  • Page 7 Do not replace battery when an explosive dust atmosphere may be present. • The replacement battery MUST be a Banner approved battery, model number BWA-BATT-001. Use of a different battery will VOID the intrinsic safety rating of this device and may result in an explosion! •...
  • Page 8 141513. Use a cable gland certified for your region and environment. For a waterproof seal, refer to the waterproofing instructions in Banner document 132607. 5. Install the terminal header onto the terminal pins. www.bannerengineering.com - Tel: +1-763-544-3164 P/N 142497 Rev. L...
  • Page 9 1/2” NPT port. Use a cable gland certified for your region and environment. For a waterproof seal, refer to the waterproofing instructions in Banner document 132607. (Not applicable for internal antenna models.) When using the stainless steel antenna feedthrough (not...
  • Page 10 SureCross DX99 FlexPower Node (Metal Housing) 10. Reconnect the space frame to the radio core unit. 11. Place the radio unit into the housing and gently push down until the spacer frame pin holes rest on the edge of the metal housing. 12.
  • Page 11: Specifications

    SureCross DX99 FlexPower Node (Metal Housing) Specifications Radio Range Supply Voltage 900 MHz, 150 mW: Up to 4.8 km (3 miles) 3.6 V dc low power option from an internal battery 2.4 GHz, 65 mW: Up to 3.2 km (2 miles) Power Consumption Minimum Separation Distance Consumption: Application dependant...
  • Page 12 SureCross DX99 FlexPower Node (Metal Housing) 110 mm 1/2” NPT internal [4.33 in] threads (2) 127 mm [5 in] 145 mm [5.7 in] 3/4” NPT internal threads 126 mm [4.96 in] 115 mm [4.5 in] 125.5 mm [4.94 in] Ø7mm [0.27 in] Included with Device (Metal Housing) The following items ship with the metal housings.
  • Page 13 Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period.