E-Stop Safety Modules with Fixed Delay –
Supply Voltage and Current
Supply Protection Circuitry
Output Configuration
Output Response Time
Input Requirements
ON-Time Delay
Status Indicators
Housing
Mounting
Vibration Resistance
Operating Conditions
Dimensions
Banner Engineering Corp.
Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164

Specifications

24V dc, ±20%
Power consumption: approx. 5 W
Protected against transient voltages and reverse polarity
Outputs K1 & K2: two redundant (total of four) safety relay (forced-guided) contacts – AgNi, gold flashed
one auxiliary N.C. contact – AgNi, gold flashed
Outputs K3 & K4: two redundant (total of four) delayed relay (forced-guided) contacts – AgNi, gold flashed
one auxiliary N.C. contact – AgNi, gold flashed
Contact ratings (all normally open and normally closed output contacts):
Max. voltage: 250V ac or 250V dc
Max. current: 4 A ac or dc
Min. current: 30 mA @ 24V dc
Max. power: 1000VA, 100W
Mechanical life: 50,000,000 operations
Electrical life: 100,000 at full resistive load
NOTE: Transient suppression is recommended when switching inductive loads. Install suppressors
across load. Never install suppressors across output contacts (see Warning, page 6).
K1 & K2: 50 milliseconds typical
K3 & K4 (ES-TN-1H1): 0.25 second
K3 & K4 (ES-TN-1H2): 0.5 second
K3 & K4 (ES-TN-1H3): 1 second
K3 & K4 (ES-TN-1H4): 2 seconds
K3 & K4 (ES-TN-1H7): 4 seconds
K3 & K4 (ES-TN-1H8): 6 seconds
K3 & K4 (ES-TN-1H9): 8 seconds
K3 & K4 (ES-TN-1H10): 10 seconds
K3 & K4 (ES-TN-1H11): 15 seconds
K3 & K4 (ES-TN-1H12): 20 seconds
Delayed Output Timing Tolerance: Set time ±100 ms or ±2%, whichever is greater
E-stop switch must have normally closed contact capable of switching 20 mA @ 24V dc.
Reset switch must have one normally open contact capable of switching 20 mA @ 24V dc.
NOTE: Inputs must be voltage-free, dry contacts.
≥ 100 ms; time from the E-stop contacts to close (Auto Reset) or the Reset button to open (Manual
Reset) and the safety outputs to close.
6 green LED indicators:
Power
Monitor
E-Stop
Out (K1 & K2 ON/OFF)
Reset
Timed-Out (K3 & K4 ON/OFF)
See page 13 for more information.
Polycarbonate. Rated NEMA 1; IEC IP40, Terminals IP20, max. terminal torque 0.8 Nm
Mounts to standard 35 mm DIN rail track. Safety Module must be installed inside an enclosure rated NEMA 3
(IEC IP54), or better.
10 to 55Hz @ 0.35 mm displacement per IEC 68-2-6
Temperature: 0° to +50°C (+32° to 122°F)
Maximum Relative Humidity: 90% @ +50°C (non-condensing)
Heat Dissipation Considerations: See page 6.
See Figure 8.
Models ES-TN-1H..
1 red LED indicator:
Fault
P/N 61061 rev. A