INSTALLATION INSTRUCTIONS
Air Flow Mode
Activates Mode Selected
Power On/Off
Rotate outer ring to
access desired mode.
Preliminary Checks
 Temporarily remove all access panels.
 Ensure that the area around the blower motor is free of sawdust, insulation, dirt, or other small loose debris.
Such material could clog the blower motor's air ducts and reduce the air fl ow through the blower motor.
 Make sure the union connection at the check valve is securely hand tightened.
 Check that the piping from the blower motor and the check valve to the butterfl y valves is properly
connected and supported.
 Ensure that cable ties or other clips support the air piping and electrical harnesses at the bath.
 Ensure that any unused electrical connectors are supported above the fl oor.
 Turn on power to the unit.
NOTE: Troubleshoot any problems using the "Troubleshooting" section.
Confi rm Blower Motor Operation
 Fill the bath to a level at least 4" (102 mm) above the top of the highest airjet.
 Press the power button on the user keypad.
 Observe that the user keypad icons illuminate. The air fl ow mode icon is lighted green. The Zone 1, Zone 2,
and Zone 3 icons are also illuminated green since all three zones are activated.
 Observe that the blower motor starts at a midrange speed.
NOTE: The purge cycle mode cannot be selected while there is water in the bath.
 Rotate the rotating ring through each of the available icon positions.
 Verify that, as each icon is selected, it begins fl ashing. If the mode is operating, the light will fl ash green. If
the mode is not operating, the icon will fl ash blue.
 Verify that, as each icon is deselected, it stops fl ashing.
 Select and activate the air fl ow mode icon.
 Press the up or down button to verify the air fl ow increases or decreases.
1107630-2-C
23 of 28

18. OPERATING SEQUENCE

Zone 1
Rotating Ring Key Pad
60" x 32" Acrylic Air Bath
Zone 2
Zone 3
Surge Mode
Increase Flow or Surge
Decrease Flow or Surge
Indicator Bar