Make Power Connections - Standard - Kallista P50047-G5 Installation Instructions Manual

60" x 32" acrylic air bath
Hide thumbs Also See for P50047-G5:
Table of Contents

Advertisement

INSTALLATION INSTRUCTIONS
120/240 VAC Source
N
L1
L2
Typical Two-Pole
Circuit Breaker
with GFCI
120 V
120 V
240 V
S/N
*Line Neutral (White)
Neutral
Bus
*Equipment Ground
NOTE: The product model number is printed on a label on the blower motor side of the bath with airjets.
This label also identifi es the electrical rating of the product. All baths with airjets come equipped with a wiring
junction box and are designed to operate between 208 VAC and 240 VAC at either 50 Hz or 60 Hz.
WARNING: Risk of electric shock. Make sure the power has been disconnected before performing the
following procedures. Refer to the "Important Information" section.
WARNING: Risk of electric shock. Connect the control to a properly grounded Ground-Fault Circuit-
Interrupter (GFCI) or Residual Current Device (RCD). This will provide additional protection against
line-to-ground shock hazard. A 220-240 V, 15 A, 50/60 Hz dedicated circuit is required.
NOTICE: The load neutral is not used. There should be no connection to the load neutral terminal on the
Ground-Fault Circuit-Interrupter (GFCI). The green wire with the yellow stripe is the equipment ground and
needs to be connected to the neutral bus in the main circuit breaker box.
NOTICE: The bath with airjets control and system have been pre-wired at the factory. A qualifi ed electrician
should make a routine service connection to the junction box.
 Connect service to the junction box. The junction box contains blue, brown, and green with a yellow stripe
colored wires. Follow local electrical codes. Bond in accordance with national and local codes.
NOTE: A wiring harness has been pre-wired at the factory, allowing communication between the keypad, all
features, and the control. No additional wiring is required, but ensure that all wires are securely fastened.
NOTE: Your wiring harness includes an antenna for the optional remote control. Do not alter or damage this
antenna during installation.
 Proceed to the "Test Run the Bath with Airjets" section.
1107630-2-C
12 of 28

6. MAKE POWER CONNECTIONS - STANDARD

Typical Wiring Connection for North America
Bond in accordance with national and local codes. Open
bonding lugs are located at the top of the junction box.
Breaker Box
*Connections to be Made
at the Circuit Breaker
*L2
240 V
*L1
No Connection
(Load Neutral)
Field Wire (From Junction
Box To GFCI Breaker)
60" x 32" Acrylic Air Bath
External Power
Control Power
Junction Box
Wire
Connector
Blue (L1)
Electrician to
provide suitable
strain relief cable.
Questions? Problems? For additional assistance, please contact KALLISTA's Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or kallista.com.
Blower
Motor Cord
Control
Power
Supply
Ground
(Green with
Yellow Stripe)
From Control
Brown (L2)