INSTALLATION INSTRUCTIONS
MOUNT THE BLOWER MOTOR AND CHECK VALVE - REMOTE (CONT.)
 Connect the check valve assembly to the new piping. Align the new pipe with the check valve assembly
and drill a hole for the existing mounting screw. Use silicone or equivalent sealant at the connection and
reuse the screw that was removed previously. Allow the sealant to cure according to the manufacturer's
recommendations.
 Apply silicone or equivalent sealant to the lower connection of the check valve assembly.
 Align the blower motor with the lower connection of the check valve assembly. Position the motor on the
support block. Reinstall the retaining screw. Allow the sealant to cure according to the manufacturer's
recommendations.
 Fasten the blower motor to the new support block with the retained mounting screws.
Cut existing cable
about 4" (102 mm)
from the blower motor.
Route the Power Cable
 Route two conductors with ground 18 AWG (American Wire Gauge) or equivalent power cable (not
supplied) between the bath and blower motor locations. Follow all applicable electrical and fi re codes.
Ensure that the cable jacket meets applicable code requirements and the cable is properly supported and
protected.
Prepare the Blower for Remote Installation
 Loosen the cable strain-relief nut on the blower motor. Push the nut back on the cable to provide clearance
for the cover removal.
 Remove the two access cover screws from the back of the blower motor. As you are loosening the screws,
check periodically if the cover can be slid back on the electrical cable.
 When the cover is loose, use electrician pliers or equivalent to cut the electrical cable at a point about
4" (102 mm) from where the cable disappears into the blower motor housing.
 Pull the free end of the electrical cord through the cover, insert, and strain relief nut.
 Discard the existing strain relief nut and insert.
 Reconnect the blower motor plug to the control.
1107630-2-C
16 of 28

10. CONNECT THE CABLE AT THE BLOWER - REMOTE

Blower Motor
Plug
60" x 32" Acrylic Air Bath
Remove two screws
to remove the cover.
Access Cover
Strain Relief
Questions? Problems? For additional assistance, please contact KALLISTA's Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or kallista.com.

Advertisement

Table of Contents
loading

Table of Contents