Make Power Connections - Remote - Kallista P50047-G5 Installation Instructions Manual

60" x 32" acrylic air bath
Hide thumbs Also See for P50047-G5:
Table of Contents

Advertisement

INSTALLATION INSTRUCTIONS
WARNING: Risk of electric shock. To reduce the risk of electric shock, connect the control to a properly
grounded Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD). This will provide
additional protection against line-to-ground shock hazard. A dedicated 220-240 V, 15 A, 50/60 Hz circuit is
required.
WARNING: Risk of electric shock. Make sure the power has been disconnected before performing the
following procedures.
NOTE: The bath with airjets model number is printed on a label near the bath blower motor. This label also
identifi es the electrical rating of the bath.
 Ensure that the control power supply cord is properly routed to the control power junction box. The control
power supply cord contains a brown wire (Line 1), a blue wire (Line 2), and a green wire with a yellow stripe
(ground or earth).
 Install a strain relief (not provided) for the power supply cable to the control power junction box.
 Route the power supply cable to the control power junction box.
 As required, strip the jacket and wire insulation on both cables in order to make the connections.
 For installations in the United States, mark any white conductor in the supply power wiring with red or black
tape as required by the NEC.
 Connect service to the control power junction box.
 Provide a separate equipment earthing or grounding conductor to the spare earth/ground lug located on
the junction box. This conductor must not be connected to any current-carrying conductor. Follow local
electrical codes.
 Bond in accordance with national and local codes.
 Clean the area of all dust and debris.
 All wiring harnesses have been pre-wired at the factory. Make sure all wires are securely fastened.
NOTE: Your wiring harness includes an antenna for the optional remote control. Do not alter or damage this
antenna during installation.
1107630-2-C
19 of 28

13. MAKE POWER CONNECTIONS - REMOTE

Second Junction Box
(Added for Remote Blower)
Remote
Blower
Power Supply Cable
New Field
Cable To
Blower Motor
60" x 32" Acrylic Air Bath
Questions? Problems? For additional assistance, please contact KALLISTA's Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or kallista.com.
Control Power
Junction Box
Control Power
Supply Cord
Blower Motor
Power Cord