INSTALLATION INSTRUCTIONS
For All Installations
This troubleshooting guide is for general aid only. A KALLISTA Authorized Service Representative or qualifi ed
electrician should correct all electrical problems. For warranty service, contact KALLISTA's Customer Service
Department at 1-888-452-5547.
Troubleshooting the Bath with Airjets System
Symptoms
1. User keypad does not illuminate
when power button is pressed or
the outer ring is rotated.
2. Ground-Fault Circuit-Interrupter
(GFCI) or Residual Current
Device (RCD) trips when bath
with airjets is turned on.
1107630-2-C
25 of 28

19. TROUBLESHOOTING PROCEDURES

Probable Causes
A. No power to control.
B. Ground-Fault Circuit-Interrupter
(GFCI) or Residual Current
Device (RCD) tripped.
C. Wiring harness from user
keypad to control is loose,
disconnected or damaged.
D. User keypad does not work.
E. Control does not work.
A. Electrical harness is wet or
damaged.
B. Electrical wiring to the bath
junction box is wet or damaged.
C. Electrical wiring to the bath
power cord is wet or damaged.
D. Blower motor is shorted
internally.
E. Control is shorted internally.
60" x 32" Acrylic Air Bath
Recommended Action
A. Check wiring and connect
power.
B. Reset GFCI or RCD. If it trips
again, refer to "Ground-Fault
Circuit-Interrupter (GFCI) or
Residual Current Device (RCD)
trips when bath with airjets is
turned on".
C. Check wiring for proper
connections. Replace the wiring
harness if necessary.
D. Replace the user keypad.
E. Replace the control.
A. Check for wet connections. Dry
the connections and repair the
leak. Check for insulation or
connector damage. Replace the
harness if damaged.
B. Have a qualifi ed electrician
diagnose and correct the
problem in accordance with
applicable building and electrical
codes.
C. Have a qualifi ed electrician
diagnose and correct the
problem in accordance with
applicable building and electrical
codes.
D. Replace the blower motor.
E. Replace the control.
Questions? Problems? For additional assistance, please contact KALLISTA's Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or kallista.com.