INSTALLATION INSTRUCTIONS
Construction Adhesive Method
 Apply a generous amount of high-quality construction adhesive to the bottom of the support blocks.
 With help, carefully move the bath into the installation area.
 Verify the support blocks are resting directly on the subfl oor. Reposition or shim as needed.
 Verify the bath is level across the top. If the bath is not level, shims must be used under the support blocks.
 Remove the protective tape from the rim.
 Apply a continuous bead of silicone sealant around the entire rim of the bath. Allow the sealant to cure
according to the manufacturer's instructions.
Mount the blower motor
using four fasteners.
2" (51 mm) Min
NOTE: The blower motor must be mounted horizontally 2" (51 mm) above the fl oor. Do not mount the blower
motor with the blower motor discharge pointing up.
NOTE: The check valve must be relocated with the blower motor. At the new location, the check valve
must be no lower than 24" (610 mm) below the rim of the bath. The check valve must be within 12" (305 mm) of
the blower motor. The check valve must be oriented vertically with the fl ow arrow pointing up.
NOTE: Refer to the "Before You Begin" section for other detailed requirements for the blower motor relocation.
 At the new blower motor location, install a 2" (51 mm) block (not supplied) for the blower motor support.
 Use the blower motor as a template to mark the location of the four mounting bolts or screws.
 Drill four 1/8" (3 mm) pilot holes for the blower motor mounting screws.
 Install and support PVC or other 1-1/2" rigid piping (not supplied) between the blower motor location and
the bath air harness.
 Connect the new piping to the existing air harness without modifying the air harness. Align the new
pipe and secure the connection with PVC cement. Allow the PVC cement to cure according to the
manufacturer's instructions.
1107630-2-C
15 of 28
SECURE THE BATH TO THE SUBFLOOR - REMOTE (CONT.)

9. MOUNT THE BLOWER MOTOR AND CHECK VALVE - REMOTE

60" x 32" Acrylic Air Bath
1-1/2" Rigid Piping
(Not Supplied)
Check
Valve
Install elbow and check valve to
field pipe, use silicone or equivalent
sealant, and install retaining screw
or equivalent fastener.
Screw
Connect blower motor to the check valve, use silicone
or equivalent sealant, and install retaining screw.
Questions? Problems? For additional assistance, please contact KALLISTA's Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or kallista.com.