INSTALLATION INSTRUCTIONS
Air Flow Mode
Activates Mode Selected
Power On/Off
Rotate outer ring to
access desired mode.
For All Installations
NOTE: For additional information on bath with airjets operation, see the "Confi rm Proper Operation" section.
Check all electrical connections, and make sure the electrical power to the bath is turned on.
Make sure all PVC piping connections are properly made.
Temporarily remove the protective drop cloth from the bath.
Ensure that the area around the blower motor is clean and free of dust or debris.
Fill the bath to a level at least 4" (102 mm) above the top of the highest airjet.
Press the power button to start the bath.
Operate the bath with air fl ow in all three zones.
Check all bath PVC connections for leaks.
Stop the blower.
Check for any water leakage at the bath, the bath drain, and the air harness.
Test other features as desired by rotating the outer ring on the keypad and pressing "OK."
Drain the bath and observe that the purge cycle starts.
Allow the automatic purge cycle to complete.
Replace the protective drop cloth in the bath.
Turn off power to the unit.
1107630-2-C
20 of 28
14. TEST RUN THE BATH WITH AIRJETS
Zone 1
Rotating Ring Key Pad
60" x 32" Acrylic Air Bath
Zone 2
Zone 3
Surge Mode
Increase Flow or Surge
Decrease Flow or Surge
Indicator Bar
Purge Mode
Questions? Problems? For additional assistance, please contact KALLISTA's Customer