General Setting; Pin Code; Entry Time; Exit Time - Blaupunkt SA 2900R User Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
6.3. GPRS. Setting
For GPRS Setting please refer to the complete manual on the following link:

6.4. General Setting

Program your system general setting under this menu. The items available include the following – see a) to g):

6.4.1. PIN Code

The PIN code is used to access the User Menu, and Arm/Home/Disarm the system. The system can store up to 4 User PIN Codes, each PIN code consists
of 4 digits. When you Arm/Home/Disarm the system, the Control Panel will record the User PIN Code used to perform the action in system log for you to
review. You can assign different User PIN Code to different family member so that the Control Panel can record the arming/disarming action of each user.
User PIN code 1 is set during the First Time setup process, it cannot be deleted.
User PIN code 2~4 are deactivated by factory defaul
To set or change the PIN Code:
1. Select the User PIN Code you want to edit, press "OK" to confirm.
2. Enter the new User PIN Code in 4-digit number, press "OK" to confirm.
3. Assign a user name to the new PIN Code, press "OK" to confirm.
6.4.2. Master Code
The Master Code is used to access the Programming Mode for system setting.
To change the Master Code, enter the new 4-digit code and press
Master Code factory default is set as

6.4.3. Entry Time

When a Door Contact (DC, PIR Detector (IR, or External PIR Detector (EIR set to Entry attribute is triggered when the system is under Away Arm or Home
Arm mode, the system will begin a countdown timer according to Entry Time setting. The system must be disarmed before the Entry Time expires, or an
alarm will be activated.
Options available are: Disable (alarm triggers immediately , 10 seconds, 20 seconds, up to 70 seconds in 10 second increments.
20 seconds
is set as factory default.

6.4.4. Exit Time

When the system is being Away Armed or Home Armed, the system will begin a countdown timer according to the Entry Time setting. When the
countdown timer expires, the system will enter the selected Arm Mode. The user must leave the premises before the timer expires.
Options available are: Disable (exit timer prohibited, 10 seconds, 20 seconds up to 70 seconds in 10 second increments.
30 seconds
is set as factory default.

6.4.5. Door Chime

This function allows you to decide whether the Control Panel should emit a two-tone Door Chime sound to notify the user when a Door Contact or PIR
Detector set to Entry is triggered under Disarmed mode.
Options available are : High, Low, Off
Door Chime Off
is set as factory default.
security.blaupunkt-service.com
OK.
1111.