Controller Replacement (Fig. 27)
IMPORTANT: Before welding on the machine, dis -
connect both battery cables from the battery, dis-
connect both wire harness plugs from the controller
and disconnect the terminal connector from the
alternator to prevent damage to the electrical sys-
tem.
1
1. Stop the engine and disconnect battery cables from
battery.
2. Disconnect wiring harness connectors from control­
ler.
3. Remove two (2) nuts securing controller to frame and
remove controller.
Figure 27
4. Install new controller and secure to frame with nuts
1. Controller
removed in step 3.
5. Connect wiring harness connectors to controller.
6. Connect battery cables.
Repairs