Linear Actuator Replacement - Toro Hydroject 3010 Service Manual

High-velocity water injection system
Hide thumbs Also See for Hydroject 3010:
Table of Contents

Advertisement

Linear Actuator Replacement (Fig. 28)
1. Put wheels in transport position (machine raised).
2. Put the machine on a level surface, stop the engine,
engage the parking brake and disconnect engine spark
plug wires.
3. Open the hood.
4. Disconnect linear actuator wire connector.
5. Disconnect extension springs.
6. Remove capscrew and nut securing each end of
linear actuator.
7. Reverse steps 3 - 6 to install the linear actuator.
Hydroject 3010
2
4
1. Linear actuator
2. Wire connector
Page 5 - 27
1
3
4
Figure 28
3. Extension spring
4. Capscrew & nut
Repairs

Advertisement

Table of Contents
loading

Table of Contents