Starting Problems (continued)
Condition
________________________________________________________________________________________________________________________________________________________
Engine cranks, but does not start.
NOTE: If engine cranks, cause of
problem is UNRELATED to inter-
lock system.
________________________________________________________________________________________________________________________________________________________
Engine cranks (but should not)
with traction bail in neutral.
________________________________________________________________________________________________________________________________________________________
Engine starts, but shuts down
when ignition key switch is re
leased to RUN position.
________________________________________________________________________________________________________________________________________________________
Starter does not disengage when
key switch is released to RUN po
sition.
Troubleshooting
Possible Cause
Engine wire harness loose.
"L" terminal on ignition key switch
loose.
Engine problem, or no fuel.
See Safety Interlock System Prob
lems.
Not electrical - regulate choke dur-
ing cold start-up.
Not electrical - low engine oil pres-
sure.
Oil pressure switch faulty.
Loose or broken wire in oil pres-
sure switch circuit.
Ignition switch faulty.
Short in start circuit wiring.
Start relay faulty.
Starter solenoid faulty.
Starter failed (mechanical).
Page 5 - 8
Correction
Connect wires.
Connect wire.
Find problem and correct (see
Chapter 3 - Engine).
Normal condition.
Find and correct cause of low en
gine oil pressure.
Test switch and replace if faulty.
Check all wiring and connections
and repair as necessary.
Test ignition key switch and re
place if faulty.
Check all wiring and connections
and repair as necessary.
Test start relay and replace if nec
essary.
Test starter solenoid and replace
if necessary.
Test starter and replace if neces
sary.
Hydroject 3010