C210
EEPROM DISPLAY - SEE MANUAL
Meaning: While using the display storage function, you entered an address that is
within the range of the EEPROM.
Each line of data on the Display Storage Data screen shows, in hexadecimal, up to
16 bytes of data beginning at the address shown at the left of the screen. In the
EEPROM, every other byte contains data; only the data bytes are shown on the
screen. In this display, therefore, the addresses at the left are incremented by 32
bytes instead of by the usual 16. Each byte of data occupies an odd-numbered
address.
If you enter an even-numbered address that is within the EEPROM, the display
begins with the next odd-numbered address.
Action: None.
C211
EXTENDED ERROR DATA LOGGED; CALL FOR ASSISTANCE
Meaning: Extended error information about an error in the 3708 was captured
because the 3708 was set to STOP ON ERROR.
Action: Write down the message ID (C2ll). Do not do any control terminal
functions that update the EEPROM. Refer to IBM 3708 Network Conversion Unit
Problem Determination for information on setting the 3708 for STOP ON ERROR.
When this message appears on the 3708 Alert Display Screen, you may press the
ENTER key to display the current alerts.
C212
RESERVED OPTION
M~aning:
Option 7, CENTRAL SITE CONFIGURATION, was selected from the
control terminal's main menu (MlOO.O), and the cartridge installed in the 3708 does
not contain the supporting microcode. To select Option 7, you must have the
cartridge with central site configuration microcode (3708 Feature 3525) installed in
the 3708.
Action: If central site configuration is desired, obtain the correct cartridge. Refer
to, Chapter 8, "Planning for Central Site Configuration" for details.
C213
HOST DOWNLOAD ATTEMPTED. PLEASE LOGOFF CONTROL TERMINAL.
Meaning: You are on the control terminal and someone is trying to download a
configuration to the 3708 over the SNA link.
Action: Log off the control terminal to permit the configuration download.
C214
WARNING: CONVERTING TO ENHANCED UDTS WILL REDUCE THE NUMBER OF UDTS
FROM SIX TO FOUR. THE FOLLOWING UDTS WILL BE CONVERTED: xl, xl, x3, and x4.
Meaning: You are performing a conversion from standard to enhanced UDTs.
Terminal types xl, x2, x3, and x4 will be converted from standard to enhanced
UDTs.
Action: Press PF6 to update the master copy of this configuration, or press PF2 to
stop this function.