CllS
PATCH AREA EXTENSION UPDATE NOT DONE DUE TO PREVIOUS ERROR
Meaning: The primary patch area in the EEPROM has failed. You should also
have received the C103 message. The patch is not in effect.
Action: Display the alert log. Write down the alert ID (Axxx) and the failure codes
for the alert screen. Keep the error information available for future service needs.
(See IBM 3708 Network Conversion Unit Problem Determination for descriptions of
the display alerts.) Try to install the patch again.
CU9
INVALID INPUT. YOU MUST ENTER AN EVEN NUMBER OF CHARACTERS
Meaning: You entered an odd number of characters into the data input field, and
an even number of characters is required.
Action: Verify your input and type in the correct data with the appropriate number
of characters.
Cl22
THE UDT TYPE BIT CANNOT BE CHANGED USING THIS PROCEDURE.
Meaning: You have tried to modify the bit that distinguishes enhanced from
standard UDTs with the UDT definition procedure.
Action: To convert between standard and enhanced UDTs, you must use option 8,
Conversion Between Standard and Enhanced UDTs, from the 3708 Configuration
and Password Menu (M120.0). The 3708 automatically changes the UDT type bit
when this procedure is successfully completed.
Cl23
TERMINAL ID xx ON PORT
yy
WILL NOT BE VALID AFTER CONVERSION. ID MUST BE
CHANGED BEFORE CONVERSION WILL TAKE PLACE.
I
I
Meaning: You are trying to convert from standard to enhanced UDTs but you have
I
TERMINAL TYPE ID
=
24 or 25 defined for at least one port.
Action: Terminal type IDs of 24 and 25 are not valid for enhanced UDTs. You can
only have four enhanced UDTs with IDs in the range of 20 to 23. If you want to
keep the UDT 24 or 25 mapping, redefine them with IDs between 20 and 23 before
converting from standard to enhanced UDTs.
Cl24
BASE TERMINAL TYPE REQUIRES ENHANCED UDTS
Meaning: You have tried to define a standard UDT from a terminal type that
requires an enhanced UDT.
Action: Perform the conversion between standard and enhanced UDTs before
attempting to define your UDT.
C200
NO MESSAGE TO DISPLAY
Meaning: You pressed PF5 to display any waiting messages, but no messages were
queued.
Action: None.
C20l
MESSAGE WAITING - PRESS PF5
Meaning: One or more messages were received and queued for display.
Action: Press PF5 to see the messages.
If
message C20l reappears, more messages·
are waiting; press PF5 again.