E680 Control Board; Warnings; Description Of The Components; Technical Specifications - FAAC B680H Manual

Hide thumbs Also See for B680H:
Table of Contents

Advertisement

1. WARNINGS

Warning - Before carrying out any work on the control board
(connections, maintenance, etc.) always:
cut off the electrical power;
install a differential magnetothermic switch with a suitable
activation threshold upstream from the system;
always separate the power cables from the control and safety
cables (button, receiver, photocells, etc.);
avoid any electrical disturbance using separate sheaths or a
shielded cable (with the shield connected to the earth).
Fig. 21
J10
M2 M1A
M1
DL15
J14
J11
ENCODER
DL1 DL2
J6
J1
3 4 5 6 7 8 9 10 11
1 2

3. TECHNICAL SPECIFICATIONS

Mains power
100-240 V~ +6% -10%
voltage
connected to switching power supply
36 V "
Continuous
power voltage
Absorbed power
240W
24 V "
Accessories
power supply
Max accessories
800 mA
current
Operating ambient
-4 °F +131 °F (-20 °C +55 °C)
temperature
Protection fuses
4 self-restoring
Pause time
Programmable
(from 0 seconds to 4.1 minutes)

E680 CONTROL BOARD

M
J5
MOTOR
POWER
J13
BATTERY
J16
DISP1
SW4
SW5
-
+
F
SW1 SW2 SW3
J15
J2
J3
12 13 14 15 16 17 18 19 20 21
22 23
2 2
4 5 6 7

2. DESCRIPTION OF THE COMPONENTS

DISP1
DL1
DL2
DL3
DL4
DL5
DL6
DL7
DL8
DL9
DL10
DL11
DL12
DL13
DL14
DL15
DL16
DL17
DL18
a
J1
J2
J12
J3
J4
J5
J6
J7
OUT5
OUT6
J10
J11
J12
J13
J14
J4
J15
2 2
J16
SW1
SW2
SW3
SW4 /SW5
M1/M1A/M2
Work time
Motor power
Motor speed
Programmability
Rapid connector
Programmable
outputs
Specifications
18
Signalling/Programming display
BUS Device status
BUS status (see paragraph 5.3)
LOOP 1 status
LOOP 2 status
Board failure signal
Not used
Encoder status
Not used
Board power supply present
OPEN input status LED
CLOSE input status LED
FSW input status LED
STOP input status LED
EMR input status LED
Released bar signal
Battery power signal
Radio channel 1 activity
Radio channel 2 activity
Input signal connector
Digital output connector
Signalling lamp connector
Detection loop connector
Motor connector
BUS 2Easy connector
Beam movement encoder connector
Connector for radio board
Released bar detection connector
Emergency battery connector
Continuous power voltage connector
USB connector for firmware upgrade
Integrated flashing traffic light connector
Beam Lights Connector
Programming key "F"
Programming key "+"
Programming key "-"
LOOP 1 / LOOP 2 calibration button
Optional module connector (Connectivity):
Programmable (from 0 to 4 minutes)
Programmable on 50 levels
Programmable on 10 levels
3 configuration levels for greater flexibility
of use
1 5-pin connector for radio board
4 programmable outputs in 19 different
functions
Deceleration management, encoder,
multi-function display, BUS technology
and built-in loop detectors

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents