Changing The Predefined Parameters Set - FAAC B680H Manual

Hide thumbs Also See for B680H:
Table of Contents

Advertisement

Display
Function
L2
Loop 2
Activating this parameter, any loop that is
connected to the Loop 2 input will serve as a
SAFETY/CLOSE function.
Y
Loop 2 enabled
no
Loop 2 disabled
(see note regarding Loop 1)
S1
Loop 1 sensitivity
Adjusts the sensitivity of the vehicle detection
loop
00
Minimum sensitivity
10
Maximum sensitivity
S2
Loop 2 sensitivity
Adjusts the sensitivity of the vehicle detection
loop
00
Minimum sensitivity
10
Maximum sensitivity
Mt
Motor movement
Using the function provided by this para-
meter makes it possible to manually move
the barrier bar, operating as dead-man.
Pressing + will open the automated system,
pressing - causes the automated system to
close.
oP
pressing +, open
cL
pressing -, close
tL
Learning
Working time and limit switch learning (see
section 7.2)
St
SYSTEM STATUS:
This allows you to choose whether to save the program-
med data upon quitting.
Y
= quit and save the data
no
= quit without saving the data
After quitting the program, press the F key to display the
status of the automated system
00
Beam closed
01
Beam open
02
Stationary ready to open
03
Stationary ready to close
04
Automated system paused
05
Opening
06
Closing
07
Failsafe in progress
08
2-EASY device verification in progress
09
Pre-flashing then OPENS
10
Pre-flashing then CLOSES
11
EMERGENCY Open
St
You can go to
then -.
Default
at any time by pressing F and
Displaying of the automated system status
important for the installing/maintenance technician in order
to distinguish the logical processes that the board carries
no
out during movement.
If, for example, the automated system status is CLOSED,
the display MUST read
received, the display will change to
enabled, or directly to
then display
Example of a status sequence displayed starting from a closed barrier
05
The sequence does not include statuses
correspond to pre-flashing when opening and closing,
respectively.
05
--
00
Beam closed
--
01
Beam open /
04
Pause
5.2 Changing the predefined parameters set
The E680 board features six sets of pre-defined configurations that
allow rapid adapting to the size of the beam installed. To select one of
the available configurations change the parameter
06
value of
to that corresponding to the barrier configuration (beam
length, type and quantity of accessories installed) given in Table 3 or
Table 4 on the next page (for example, choose the default
beam type "L" of 17.4 ft (5.3 m) with lights).
To complete the configuration, it is necessary to exit the Basic
Configuration menu by pressing "F" until parameter
or by pressing "F" and "-"
This operation changes the value of the parameters
So
and
in Advanced configuration, setting them on the default 
values as shown in the tables in paragraph 6.3.
Setting a set of pre-defined parameters that does not 
correspond to the actual configuration of the barrier could 
cause irreversible damage to the automated system, in
particular if the default corresponds to a beam length
shorter than the actual one.
22
00
. When the OPEN command is
09
05
(the OPENING movement) to
01
once the position of gate OPEN is reached).
09
05
Opening
06
Closing
SC
in Basic configuration and  
St
is extremely
, if pre-flashing is
10
and
which
cF
from the default
04
for a
St
is reached
FO
FC
oc
,
,