6. Advanced Configuration
To access Advanced Configuration, press F and, while holding it,
+
also press
:
+
when
is released, the number of the first available function
will appear
when F is also released, the value is displayed, and can be
+
-
changed using
and
pressing F again, and holding it, the name of the next parameter
will be displayed; when released, the value can be changed
+
-
using
and
once the last function has been reached, pressing F makes it
possible to either save the previously changed parameters or exit
without saving the changes; the display will go back to showing
the status of the inputs.

ADVANCED CONFIGURATION

Display
Function
FO
Opening motor force
Adjusts the thrust of the motor during the ope-
ning phase.
00
Minimum power
50
Maximum power
FC
Closing motor force
Adjusts the thrust of the motor during the closing
phase.
00
Minimum power
50
Maximum power
PF
Pre-flashing
This parameter is used to activate the flashing
lamp for 5 seconds before the selected
movement.
no
disabled
OC
before each movement
CL
before each closing movement
OP
before each opening movement
PA
only at the end of the pause
tP
Pre-flashing time
Pre-flashing time expressed in seconds.
00
minimum pre-flashing
10
maximum pre-flashing
Display
Function
oc
Sensitivity of obstacle during closing
This determines the sensitivity to an obstacle
before reversing takes place.
01
Minimum sensitivity
50
Maximum sensitivity
o1
Output 1
Setting this function makes it possible to modify
the signal type of output 1, allowing high
connection flexibility with external devices.
00
Failsafe
0 1
TYPE
(output active when beam closed,
disabled with bar open or paused,
intermittent when moving). Use only
with output 4!
02
Default
BAR LIGHTING TYPE 2 (flashing
output during opening, closing and with
rod closed or stopped. inactive with rod
40
open or paused).
03
Beam CLOSED
04
Beam OPEN or in PAUSE, it goes off
during closing pre-flashing.
05
Beam in OPENING MOVEMENT,
including pre-flashing.
40
06
Beam in CLOSING MOVEMENT,
07
Beam STATIONARY
08
Beam in EMERGENCY mode
09
LOOP1 engaged
no
10
LOOP2 engaged
11
OPEN for E680 slave
12
CLOSE for E680 slave
13
Beam RELEASED
14
Not used
15
Not used
16
FCA engaged
17
FCC engaged
18
Interlock
19
WARNING LAMP (on during opening
00
and pause, flashing when closing, off
when the automated system is closed)
20
Battery operation
P1
Output 1 Polarity
Allows setting of the output polarity:
Y
output NC
no
output NO
NOTE: if the output setting is
keep the value set to
o2
Output 2
Output 2 signal type, see "Output 1"
24
1
BEAM
ILLUMINATION
including pre-flashing.
00
(Failsafe),
no
Default
30
04
no
03

Hide quick links: